Technical Data
Technical Data
Conforms to: ISO 8502-4, BS7079-B
and ASTM D3276
Range
Accuracy
Resolution
Surface
Temperature
-40° to 80° C
80° to 190° C
-40° to 175° F
175° to 375° F
±0.5° C
±1.5° C
±1° F
±3° F
0.1° C
0.1° C
0.1° F
0.1° F
Air
Temperature
-40° to 80° C
-40° to 175° F
±0.5° C
±1° F
0.1° C
0.1° F
Humidity
0 to 100%
±3 %
0.1 %
Dew Point
Temperature
-60° to 80° C
-76° to 175° F
±3° C*
±5.4° F*
0.1° C
0.1° F
*
Dependent on RH. See www.defelsko.com/TdAccuracy
for more information.
Operating Range:
-10° to 60° C (14° to 140° F)
Memory:
10,000 datasets
@ 5 min interval = 34 days
@ 10 min interval = 68 days
Interface:
BLE Bluetooth Smart
Logging Interval:
Adjustable from 1 min – 8 hours
IP Rating:
65
Power Source:
one CR2032 coin cell
Battery Life^:
@ 5 min interval = 120 days
@ 1 hour interval = 200 days
^
The stated battery life is for unattended logging. Battery life is reduced
while connected to the PosiTector App or instrument.