• Connect each sensor in use to the correct current sensor input on homeCLU.
›
NB! Phase dependent; follow the installation diagrams. See also section "11. Charge
controller address vs. current sensor input".
• Connect the 12V DC cable between the power supply and homeCLU. Screw
terminal installation torque: 0,4-0,6Nm.
• Route the communication cables away from line-voltage elements. Do not route the
homeCLU cables in parallel with the supply lines. Secure the cables with nylon cable ties
to suitable fixing points.
• Power up homeCLU by connecting 230V AC to the power supply. Screw terminal
installation torque: 0,4-0,6Nm.
›
Warning! Check connections before powering!