background image

SeaLite

®

 

Lumos

Operator’s Manual

5

Troubleshooting 

I

f the light stops working while underwater assume that 

it has been flooded. See Flooded Light Repair procedure 
below. 

Once it has been determined that the light is not flooded, 
or if it does not turn on during pre-deployment checks, 
check the input power cable/inline connector to make 
sure that correct voltage is being supplied, and that the 
correct pinout is being used. See page 2 of this manual 
for electrical specs and connector pin assignments. 

If the light still does not work, return it to DSPL using the 
RMA Procedure for Repair below.

Flooded Light Repair

If the light stops working while underwater, you should 
assume that it has been flooded. When working on a 
potentially flooded light, it is important to use appropriate 
personal protective equipment to include, at a minimum, 
eye and hand protection.

1.  Place the light face down on a table making sure 

that the connector side is facing up.

2.  Slowly unscrew the connector/socket assembly to 

allow any internal pressure to be equalized.

3.  Once it is determined that the light is not 

internally pressurized, it is recommended that 
the light be returned to DeepSea Power & Light 
(DSPL) for evaluation and repair using the RMA 
Procedure.

RMA Procedure for Repair

Should it be necessary to return your light to the factory, 
follow the procedure for the Flooded Light Repair above, 
leaving the connector partially unscrewed. For warranty 
and non-warranty repairs please contact DeepSea 
Power & Light for a RMA number prior to returning 
your item. Please have your light model number, serial 
number and any other pertinent information along with 
a description of the problem, on hand when you call, or 
include them in a fax or e-mail. When shipping your item, 
be sure that the freight is pre-paid (CODs will not be 
accepted) and that the RMA number is clearly printed on 
the outside of the box.

All shipments should be sent to the address below:

DeepSea Power & Light
Attn: RMA ####
4033 Ruffin Road
San Diego, CA 92123-1817
U.S.A

Tel: (858) 576-1261
Fax: 858-576-0219
e-mail: [email protected]

Limited Warranty

Seller warrants that the goods (except internal electronic 
components) sold under this contract will be free from 
defect in material and workmanship for a period of 
one year from the date of shipment from the factory, 
if they have been properly used. Internal electronic 
components are warranted for 90 days from the date 
of shipment from the factory, if they have been properly 
used. This warranty will be limited to the repair or 
replacement of parts and the necessary labor and 
services required to repair the goods. IT IS EXPRESS 
LY AGREED THAT THIS WARRANTY WILL BE IN LIEU 
OF ALL WARRANTIES OF FITNESS AND IN LIEU 
OF THE WARRANTY OF MERCHANTABILITY. This 
warranty is the exclusive and only warranty to pass with 
the goods under this contract. No agent, employee, or 
representative of the Seller has any authority to bind 
Seller to any information, representation, or warranty 
concerning the goods sold under this contract, and 
unless an affirmation, representation, or warranty 
made by an agent, employee, or representative is 
specifically included within this contract, it will not be 
enforceable by Buyer. If notice of defect is given to 
DeepSea Power & Light, Inc. within such 90 day or one 
year warranty period, the sole obligation of DeepSea 
Power & Light, Inc. shall be to furnish new or repaired 
parts free of charge in exchange for parts which have 
been proved defective and does not include any other 
costs such as the cost of removal of the defective part, 
installation, labor, or consequential damages of any 
kind, the exclusive remedy being to require DeepSea 
Power & Light, Inc. to furnish such new parts. Under 
no circumstances shall the Buyer be entitled to recover 
any incidental damages as that term is defined in 
Commercial Code §2715.

www.deepsea.com

[email protected]

4033 Ruffin Road

San Diego, CA 

92123-1817 USA

T: (800) 487-3775

F: (858) 576-0219

Содержание SeaLite Lumos 1000

Страница 1: ...late Serial Pin out Postive Pin Negative Pin Ground Pin Dimming if applicable Pin DEEPSEA POWER LIGHT Operator s Manual T 858 576 1261 F 858 576 0219 4033 Ruffin Road San Diego CA 92123 1817 USA www deepsea com sales deepsea com Original Instruction REV 07 01 15 SeaLite Lumos ...

Страница 2: ...ot 32º Electrical Specifications Lumos 2000 Lumos 1000 Input Voltage 10 36V DC 90 270V AC 50 60Hz 100 350V DC Current 1 10A 24V DC 2 65A 10V DC 0 27A 120V AC 0 13A 240V AC Power 26 5W max 32 0W max Dimming 0 5V DC AC phase control TRIAC variable voltage VARIAC Dimensions 1 87 47 5 1 69 42 9 2 47 62 6 2 40 60 9 1 59 40 3 59 15 6 08 154 3 7 35 186 7 1 85 47 1 00 25 4 1 00 25 4 4X 1 4 20 UNC OR 4X M6...

Страница 3: ...Symbols 4 General Notes and Warnings 4 Pre Dive Inspection 4 Post Dive Inspection 4 5 Troubleshooting 5 Flooded Light Repair 5 Limited Warranty 5 RMA Procedure for Repair 5 Appendix A Dimming Response Curve 6 Appendix B Driver Efficiency 9 Appendix C LVDC Step Response Curve 11 Appendix D Beam Patterns 14 ...

Страница 4: ...ir the body may reach temperatures in excess of 65 C These temperatures may be enough to cause burns if the light is handled without protective clothing Do not operate any high voltage electrical equipment in or around water without using a Ground Fault Interrupt circuit GFI and an isolation transformer especially when divers are in the water WARNING Do not clean any part of the light head with an...

Страница 5: ... outside of the box All shipments should be sent to the address below DeepSea Power Light Attn RMA 4033 Ruffin Road San Diego CA 92123 1817 U S A Tel 858 576 1261 Fax 858 576 0219 e mail RMA deepsea com Limited Warranty Seller warrants that the goods except internal electronic components sold under this contract will be free from defect in material and workmanship for a period of one year from the...

Страница 6: ...SeaLite Lumos Operator s Manual 6 Appendix A Dimming Response Curves ...

Страница 7: ...put Input Phase Angle SeaLite Lumos 1000 Phase Cut Dimming Response SLL 1000 120VAC 60Hz SLL 1000 240VAC 50Hz 0 20 40 60 80 100 0V 20V 40V 60V 80V 100V 120V 140V 160V Output Input RMS Voltage SeaLite Lumos 1000 Variable Voltage Dimming Response SLL 1000 120VAC 60Hz SLL 1000 High Voltage DC ...

Страница 8: ...SeaLite Lumos Operator s Manual 8 0 20 40 60 80 100 0 0V 1 0V 2 0V 3 0V 4 0V 5 0V 6 0V Output Dimming Input Voltage SeaLite Lumos 2000 Analog Dimming Response ...

Страница 9: ...SeaLite Lumos Operator s Manual 9 Appendix B Driver Efficiency ...

Страница 10: ...V 310V 360V Efficiency Input RMS Voltage SeaLite Lumos 1000 Efficiency SLL 1000 VAC 60Hz SLL 1000 VAC 50Hz SLL 1000 DC 0 0 5 1 1 5 2 2 5 3 3 5 0 20 40 60 80 100 6V 12V 18V 24V 30V 36V Current A Efficiency Input DC Voltage SeaLite Lumos 2000 Efficiency Efficiency Input Current ...

Страница 11: ...SeaLite Lumos Operator s Manual 11 Appendix C Low Voltage DC Step Response Curve ...

Страница 12: ...SeaLite Lumos Operator s Manual 12 0 10 20 30 40 50 60 70 80 90 100 0V 1V 2V 3V 4V 5V 10 0 10 20 30 40 50 Output Control Pulse V Time ms SLL 2000 DIM Input Step Response Characteristics Trigger Output ...

Страница 13: ...SeaLite Lumos Operator s Manual 13 DIM Input Pulse Response Rise Time SLL 2000 LVDC DIM Input Pulse Response Fall Time SLL 2000 LVDC ...

Страница 14: ...SeaLite Lumos Operator s Manual 14 Appendix D Beam Patterns ...

Страница 15: ...550 SeaLite Lumos Spot SLL 1000 DW S PV SeaLite Lumos Flood SLL 2000 DW F A05 2607 0 1000 2000 3000 4000 5000 6000 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Radial Lux Intensity Comparison 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 0 0 10 0 20 0 30 0 40 0 50 0 60 0 70 0 80 0 90 0 0 25 50 75 100 Degrees Output Angular Distribution ...

Отзывы: