SeaLite
®
Lumos
Operator’s Manual
5
Troubleshooting
I
f the light stops working while underwater assume that
it has been flooded. See Flooded Light Repair procedure
below.
Once it has been determined that the light is not flooded,
or if it does not turn on during pre-deployment checks,
check the input power cable/inline connector to make
sure that correct voltage is being supplied, and that the
correct pinout is being used. See page 2 of this manual
for electrical specs and connector pin assignments.
If the light still does not work, return it to DSPL using the
RMA Procedure for Repair below.
Flooded Light Repair
If the light stops working while underwater, you should
assume that it has been flooded. When working on a
potentially flooded light, it is important to use appropriate
personal protective equipment to include, at a minimum,
eye and hand protection.
1. Place the light face down on a table making sure
that the connector side is facing up.
2. Slowly unscrew the connector/socket assembly to
allow any internal pressure to be equalized.
3. Once it is determined that the light is not
internally pressurized, it is recommended that
the light be returned to DeepSea Power & Light
(DSPL) for evaluation and repair using the RMA
Procedure.
RMA Procedure for Repair
Should it be necessary to return your light to the factory,
follow the procedure for the Flooded Light Repair above,
leaving the connector partially unscrewed. For warranty
and non-warranty repairs please contact DeepSea
Power & Light for a RMA number prior to returning
your item. Please have your light model number, serial
number and any other pertinent information along with
a description of the problem, on hand when you call, or
include them in a fax or e-mail. When shipping your item,
be sure that the freight is pre-paid (CODs will not be
accepted) and that the RMA number is clearly printed on
the outside of the box.
All shipments should be sent to the address below:
DeepSea Power & Light
Attn: RMA ####
4033 Ruffin Road
San Diego, CA 92123-1817
U.S.A
Tel: (858) 576-1261
Fax: 858-576-0219
e-mail: [email protected]
Limited Warranty
Seller warrants that the goods (except internal electronic
components) sold under this contract will be free from
defect in material and workmanship for a period of
one year from the date of shipment from the factory,
if they have been properly used. Internal electronic
components are warranted for 90 days from the date
of shipment from the factory, if they have been properly
used. This warranty will be limited to the repair or
replacement of parts and the necessary labor and
services required to repair the goods. IT IS EXPRESS
LY AGREED THAT THIS WARRANTY WILL BE IN LIEU
OF ALL WARRANTIES OF FITNESS AND IN LIEU
OF THE WARRANTY OF MERCHANTABILITY. This
warranty is the exclusive and only warranty to pass with
the goods under this contract. No agent, employee, or
representative of the Seller has any authority to bind
Seller to any information, representation, or warranty
concerning the goods sold under this contract, and
unless an affirmation, representation, or warranty
made by an agent, employee, or representative is
specifically included within this contract, it will not be
enforceable by Buyer. If notice of defect is given to
DeepSea Power & Light, Inc. within such 90 day or one
year warranty period, the sole obligation of DeepSea
Power & Light, Inc. shall be to furnish new or repaired
parts free of charge in exchange for parts which have
been proved defective and does not include any other
costs such as the cost of removal of the defective part,
installation, labor, or consequential damages of any
kind, the exclusive remedy being to require DeepSea
Power & Light, Inc. to furnish such new parts. Under
no circumstances shall the Buyer be entitled to recover
any incidental damages as that term is defined in
Commercial Code §2715.
www.deepsea.com
4033 Ruffin Road
San Diego, CA
92123-1817 USA
T: (800) 487-3775
F: (858) 576-0219
Содержание SeaLite Lumos 1000
Страница 6: ...SeaLite Lumos Operator s Manual 6 Appendix A Dimming Response Curves ...
Страница 9: ...SeaLite Lumos Operator s Manual 9 Appendix B Driver Efficiency ...
Страница 11: ...SeaLite Lumos Operator s Manual 11 Appendix C Low Voltage DC Step Response Curve ...
Страница 14: ...SeaLite Lumos Operator s Manual 14 Appendix D Beam Patterns ...