background image

How to repair the Alliance machine without disassembling it

If you need to access the interior of the mixing shelves 
to replace a belt or repair some components, it is 
possible to access any of the  shelves without 

disassembling the entire machine.

To do so:

1. Turn off the power to your Alliance mixing machine.

2. Remove the cans from the shelf you wish to access.

3. Remove the shaft guard from around the drive shaft.
4. Lift the shelf cover straight up on both the left and  

    the right side.
5. Support the raised shelf with an object(s) to prevent  
    it from falling back into place.
You should now be able to access any of the internal 
parts you need.

5

4

3

2

Gallon/4 Liter Drive Shaft

(33.35 cm, 13 1/8") 

Quart/1 Liter Drive Shaft

(25.4 cm, 10")

Quart/1 Liter Motor Drive Shaft

(13.5 cm, 5-1/4") 

Gallon/4 Liter Motor Drive Shaft

(21.45 cm, 8-1/2") 

PN# 5996PLT 

PN# 5995PLT 

PN# P1243 

PN# P1244 

How to remove the drive shafts

Once the expanding bolt has been removed (See “How to 

remove the expanding bolt”) the drive shafts can be removed.
1. Turn off the power to your Alliance mixing machine.
2. Pull the shaft guards off of each shaft.
3. Lift the shafts straight up and out beginning with the top shaft.
4. To remove a shaft, the one above it must be removed first.
5. It is good practice to lift the shafts that you do not need to  

    repair or replace and let them stand aside on the shelves  
    below without fully removing them. This will prevent loss or  

    misplacement of the shafts during reassembly.
Note: Depending on your choice for the bottom shelf (Quart or 

Gallon) you may need either the Quart or Gallon motor drive 

shaft. When replacing either of these two shafts you will also 

need to replace the expanding bolt.

Содержание Alliance

Страница 1: ...s installed in the drive gear in the top mixing unit of your fully assembled Alliance machine It s purpose is to hold all of the shafts from the lower mixing shelves in place so they will not move during operation To remove the expanding bolt 1 Turn off the power to your Alliance mixing machine 2 Remove the header from the top of your machine 3 Remove the shelf cover from the top mixing shelf of yo...

Страница 2: ...t 1 Liter Motor Drive Shaft 13 5 cm 5 1 4 Gallon 4 Liter Motor Drive Shaft 21 45 cm 8 1 2 PN 5996PLT PN 5995PLT PN P1243 PN P1244 How to remove the drive shafts Once the expanding bolt has been removed See How to remove the expanding bolt the drive shafts can be removed 1 Turn off the power to your Alliance mixing machine 2 Pull the shaft guards off of each shaft 3 Lift the shafts straight up and ou...

Страница 3: ...ve gear should snap and secure it in place against the bottom of the bushing Note It is good practice to check that all of the other drive gears are snapped into place and seated correctly before replacing all of the shafts The drive gears may become dislodged while moving the shafts Drive Gear PN 5931 Bushing PN 5278E M Drive Gear Drive Gear Lip Bushing Mix Shelf Lower Shaft Upper Shaft Periodic ...

Страница 4: ...e shaft 4 Loosen the shoulder bolt and locknut of the left pulley of the drive system to loosen the tension on the belt 5 Carefully remove the loosened belt from the drive system 6 Clean the interior of the shelf from dirt and debris This may be a good time to lubricate your mix shelf as well See How to lubricate your Alliance machine 7 Install the new belt with the cogs facing outward while follo...

Страница 5: ...n disconnecting the wires as the connections are very tight and damage to the wires or connectors may result 4 Connect the GREEN wire into the location labeled BYPASS GREEN 5 Turn power on to the machine Once you restore power to the machine the motor should begin to operate without having to use the timer Note The bypass operation is for diagnosing motor or timer problems It is not intended to be...

Страница 6: ... See How to repair your machine without disassembling it 3 Using a flat screw driver push into the slots that secure the interface to the mixing shelf on each side See Figure 1 4 Pull the loosened interface down and away from the mixing shelf Note The interface may break or crack during removal To install a new interface 1 Place the back tab of the interface into the opening on the mixing shelf 2 P...

Страница 7: ...ommend that you check your machine for alignment every six to eight months of operation We also suggest that after completing and repairs or part replacement on a machine that you check to ensure alignment is correct as well The wall anchors that were supplied in the motor box of your machine are very important to help retain alignment over time They secure the top of the machine to the wall This ...