7
08/06/06 - 300008460-001-B
MCR 24, 24/28 MI, 30/35 MI, 34/39 MI
4 Technical data
1 mbar = 100 Pa - 1 daPa ~ 1 mm H
2
O
Cold water temperature: 10 °C; Domestic hot water temperature:
85 °C
Boilers
MCR 24
MCR 24/28MI
MCR 30/35MI
MCR 34/39MI
Nominal useful output 40/30 (Heating mode) (min./max)
kW
6.3/25
6.3/25
6.6/31.3
6.8/35.5
Nominal useful output 80/60 (min./max)
kW
5.5/23.6
5.5/23.6
5.7/29.5
5.9/33.3
Nominal useful output (DHW mode) (min./max)
kW
-
27.4
34.3
38.2
Nominal input power (heating and DHW modes)
kW
24/24
24/28
30/35
34/39
Minimum useful output 40/30 (Heating mode)
kW
6.3
6.3
6.6
6.8
Minimum input power (heating and DHW modes)
kW
5.8
5.8
6.1
6.3
Gas flow rate à Pn (à 15°C - 1013 mbar):
Natural gas H
Natural gas L
Propane
kW
m
3
/h
m
3
/h
Kg/h
24
2.4
2.8
1.9
24
2.4
2.8
1.9
35
3.5
4.1
2.7
39
3.9
4.5
3.0
PCI efficiency, Load and water temperature efficiency:
100% Nominal power, Average temperature: 70 °C
100% Nominal power, Return temperature: 30 °C
30% Nominal power, Return temperature: 30 °C
%
%
%
98.3
104.4
108.7
98.3
104.4
108.7
98.2
104.4
109.7
98
104.4
110.5
Maximum temperature (Safety thermostat cut-off)
°C
110
110
110
110
Losses when off (
∆
T = 30 °C)
W
30
30
29
28
Losses through the outer casing
%
1.1
1.1
0.9
0.5
Water capacity
l
1.7
1.8
2
2.2
Weight without water, without mounting frame, without cladding
kg
29
30.5
32
31.5
Specifications of the heating circuit
Nominal water flow (
∆
T = 20 K)
l/h
1.03
1.03
1.29
1.47
Rated net head (
∆
T = 20 K)
mbar
>200
>200
>200
>200
Flow temperature
°C
75
75
75
75
Maximum pressure
bar
3
3
3
3
Expansion chamber
l
8
8
8
-
Initial pressure of the expansion tank
bar
1
1
1
1
Minimum operating pressure
bar
0.8
0.8
0.8
0.8
Domestic hot water specifications
Instruction set outlet temperature
°C
55
55
55
55
Specific hot water flow (
∆
T = 30 K)
l/min
-
14
16
19
Nominal max cold water pressure
bar
8
8
8
8
Minimum pressure (11 l/min)
bar
-
1.4
0.4
0.4
Combustion products circuit
Connecting
diameter
(mm)
60/100
60/100
60/100
60/100
Mass flue gas flow rate (min./max)
Kg/h
10/40
10/47
10/59
10/62
Flue gas temperature 80/60
°C
78
78
74
71.5
Pressure available at the flue gas nozzle
Pa
50
100
100
140
Condensation water pH 50/30
- 1-7
1-7
1-7
1-7
Electrical specifications
Power supply voltage (50 Hz)
V
230
230
230
230
Power consumption
W
115
115
150
180
Electrical output circulating pump
W
90
90
125
135
Auxiliary electrical output (Nominal power, ex circulating pump)
W
25
25
25
45
Insulation class
IPX4D
IPX4D
IPX4D
IPX4D