MCR 24, 24/28 MI, 30/35 MI, 34/39 MI
08/06/06-300008460-001-B
1.8
Electrical connection (230 V)
The boilers are delivered pre-fitted with a 3-conductor power supply
cable with an available length of around 1.5 metres.
The appliance must be powered by a circuit containing an omnipolar
switch with an opening distance 3 mm.
Only qualified professionnals may carry out electrical
connections, always with the power off.
When connecting to the mains, be sure to respect live for the brown
wire, neutral for the blue wire and earth for the green/yellow wire.
For B Certain European countries
If you use a two-phase electrical grid, jumper must be removed
(130 V: Lane/Neutral).
The boiler is not sensitive to phase reversal.