BL 150
BL 200
BL 300
BL 400
BL 500
Multi-voltage shielded resistor
4.5 kW
-
-
-
EC 413
EC 413
Multi-voltage steatite heating
resistance
2.4 kW
-
EC 411
-
-
-
Multi-voltage steatite heating
resistance
3 kW
-
-
EG 88
(2)
-
-
SLA2 control system for load
pump
EC 320
EC 320
EC 320
EC 320
EC 320
(1) The titanium anode can only be fitted to the DHW tank if this is connected to a boiler equipped with a Diematic 3 control panel which
incorporates the TAS ® function.
(2) The EG 88 steatite heating resistance must be accompanied by the installation of the AJ 38 impressed current anode in the top buffer tank
in order to ensure adequate protection of the tank against corrosion.
WARNING
4
The impressed current anode and the shielded
electrical resistor cannot be fitted simultaneously.
4
Respect the recommended anode / electrical resistor
combinations as the electrical resistor is combined
with a magnesium anode which, with the anode in the
top section already in place, is calculated to protect
the enamelled tank correctly.
4.3
Choice of the location
4.3.1.
Data plate
The nameplate affixed to the tank provides important information
regarding the appliance: serial number, model, etc.
CAUTION
The rating plate must be accessible at all times.
4.3.2.
Location of the appliance
CAUTION
Put the appliance in a frost-free location.
4
Place the appliance as close as possible to draw-off points in order
to minimise energy losses through the pipes.
4
Place the appliance on a base frame to facilitate cleaning of the
premises.
4. Installation
BL 150...500
11
01/03/2011 - 300019417-001-C
Содержание BL 150
Страница 4: ...3 01 03 2011 300019417 001 C ...
Страница 19: ...4 7 2 Fitting the DHW sensor D000882 1 3 2 4 5 3 BL 150 500 4 Installation 01 03 2011 300019417 001 C 18 ...
Страница 37: ...BL 150 500 8 Warranty 01 03 2011 300019417 001 C 36 ...
Страница 38: ......
Страница 39: ......