Tab.33 Weighting of medium temperature heat pumps
II, package without hot water storage tank
II, package with hot water storage tank
0
1.00
1.00
0.1
0.70
0.63
0.2
0.45
0.30
0.3
0.25
0.15
0.4
0.15
0.06
0.5
0.05
0.02
0.6
0.02
0
≥ 0.7
0
0
(1) The intermediate values are calculated by linear interpolation between the two adjacent values.
(2) Prated is related to the preferential space heater or combination heater.
Tab.34 Package efficiency
Unit AWHP 4.5 MR AWHP 6 MR-3 AWHP 8 MR-2
Seasonal space heating energy efficiency of package
%
136
127
131
Tab.35 Package efficiency
Un
it
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
AWHP 22
TR–2
AWHP 27
TR–2
Seasonal space heating energy efficiency of
package
% 127
127
123
123
116
114
10 Appendix
10.1 Name and symbol of the zones
Tab.36
Factory-set name
Factory-set symbol
Name and symbol defined by the customer
CIRCA0
CIRCA1
CIRCB1
CIRCC1
CIRCAUX1
10.2 Name and temperature of the activities
Tab.37 Name and temperature of the activities for heating
Activities
Factory-set name
Factory-set tempera
ture
Name and temperature defined by the customer
Activity 1
Sleep
16 °C
Activity 2
Home
20 °C
Activity 3
Away
6 °C
Activity 4
Morning
21 °C
Activity 5
Evening
22 °C
Activity 6
Custom
20 °C
10 Appendix
7684505 - v04 - 10022022
MIT-S
33