Unit
AWHP 4.5 MR AWHP 6 MR-3 AWHP 8 MR-2
Seasonal space heating energy efficiency under average cli
mate conditions
%
134
125
129
Annual energy consumption under average climate conditions
kWh
2353
2124
3499
Sound power level L
WA
dB (A)
43
43
51
Rated heat output, under colder - warmer climate conditions
kW
5 – 4
4 - 5
6 - 6
Seasonal space heating energy efficiency, under colder - warm
er climate conditions
%
109 – 179
116 - 172
119 - 169
Annual energy consumption, under colder - warmer climate con
ditions
kWh
4483 – 1249
3721 - 1492
4621 - 1904
Sound power level L
WA
outdoors
dB (A)
58
65
65
(1) If applicable
Tab.30 Product fiche for heat pump space heaters
Unit
AWHP 11
MR-2
AWHP 11
TR-2
AWHP 16
MR-2
AWHP 16
TR-2
Space heating energy efficiency class under average
climate conditions
A
++
A
++
A
+
A
+
Rated heat output under average climate conditions
(Prated or Psup)
kW
6
6
9
9
Seasonal space heating energy efficiency under aver
age climate conditions
%
125
125
121
121
Annual energy consumption under average climate con
ditions
kWh
3999
3999
5861
5861
Sound power level L
WA
indoors
dB (A) 51
51
51
51
Rated heat output, under colder - warmer climate condi
tions
kW
4 - 8
4 - 8
7 - 13
7 - 13
Seasonal space heating energy efficiency, under colder
- warmer climate conditions
%
113 - 167
113 – 167
113 - 161
113 - 161
Annual energy consumption, under colder - warmer cli
mate conditions
kWh
3804 - 2580
3804 - 2580
5684 - 4120
5684 - 4120
Sound power level L
WA
outdoors
dB (A) 65
65
69
69
(1) If applicable.
Tab.31 Product fiche for heat pump space heaters
Unit
AWHP 22 TR–2
AWHP 27 TR–2
Space heating energy efficiency class under average climate conditions
A
+
A
+
Rated heat output under average climate conditions
(Prated or Psup)
kW
11
14
Seasonal space heating energy efficiency under average climate conditions
%
114
112
Annual energy consumption under average climate conditions
kWh
7681
9993
Sound power level L
WA
indoors
dB (A)
43
43
Rated heat output, under colder - warmer climate conditions
kW
12 - 18
14 - 20
Seasonal space heating energy efficiency, under colder - warmer climate
conditions
%
111 - 143
103 – 141
Annual energy consumption, under colder - warmer climate conditions
kWh
10578 - 10025
13164 - 11541
Sound power level L
WA
outdoors
dB (A)
70
77
(1) If applicable.
See
For specific precautions about assembling, installing and
maintaining: See Safety
9 Product fiche and package fiche
30
MIT-S
7684505 - v04 - 10022022