3.2.2
Heat pump weight
Tab.6
Indoor module
Indoor module
Unit
MIV-4S/E 4-8 V200
MIV-4S/H 4-8 V200
MIV-4S/E 11-16
V200
MIV-4S/H 11-16 V200
Weight (empty)
kg
138
137
140
139
Total weight with
water
kg
333
332
335
334
Tab.7
Outdoor unit
Outdoor unit
Unit
AWHP 4.5 MR
AWHP 6 MR-3
AWHP 8 MR-2
AWHP 11 MR-2
AWHP 16 MR-2
AWHP 11 TR-2
AWHP 16 TR-2
Weight (empty)
kg
54
42
75
118
130
3.2.3
Domestic hot water tank
Tab.8
Technical specifications primary circuit (heating water)
Specification
Unit
Value
Maximum operating temperature
Version with hydraulic back-up
°C
90
Maximum operating temperature
Version with electrical back-up
°C
75
Minimum operating temperature
°C
7
Maximum operating pressure
MPa (bar)
0.3 (3.0)
Domestic hot water tank exchanger capacity
Litres
11.3
Exchange surface
m²
1.7
Tab.9
Technical specifications secondary circuit (domestic water)
Specification
Unit
Value
Maximum operating temperature
°C
80
Minimum operating temperature
°C
10
Maximum operating pressure
MPa (bar)
1.0 (10.0)
Water capacity
Litres
177
Tab.10 Common specifications (in accordance with the EN 16147 standard). Water set point temperature: 53 °C (except for
AWHP 4.5 MR: 54 °C) – Outdoor temperature: 7°C – Inside air temperature: 20°C
AWHP 4.5 MR
(cycle M)
AWHP 6 MR-3
(cycle L)
AWHP 8 MR-2
(cycle L)
AWHP 11 MR-2
AWHP 11 TR-2
(cycle L)
AWHP 16 MR-2
AWHP 16 TR-2
(cycle L)
Charging time
1 hour 40 minutes 2 hours
1 hour 58 minutes 1 hour 33 minutes 1 hour 11 minutes
Coefficient of performance
domestic hot water
(COP
DHW
)
2.50
2.72
2.72
2.72
2.72
3 Technical specifications
14
MIV-4S V200
7682822 - v03 - 27082018