DeCrane Aerospace Audio International                                    LCDW-9320-101-x Installation Manual  

 

Document # 540363, Rev A1, 11/2008 

 

Page 5 of 18

 

2.4.2 

The Digital Video Input accepts SD-SDI video as defined 

by ANSI/SMPTE 259M-1997.  

 

2.4.3 

SP-LCD6 is an external switch utilized for monitor set-up. 

The switch, which must be ordered separately, provides 

configuration  control  via  DeCrane  Aerospace  Audio 

International’s  proprietary  RS-485  digital  data  bus 

communication  or  may  be  configured  directly  to  the  J2 

connector. Refer to Section 3.8, Configuration Overview, 

for  monitor  set  up.  The  SP-LCD6  may  be  removed  and 

stored after the monitor is set up or can be mounted near 

the  monitor  for  frequent  use.  Connector  J2  provides  to 

the switch panel +28 VDC power and ground input, serial 

data  bus  control,  and  unit  ID  strapping  pins  to  allow 

programming of multiple units.  

 

2.4.4 

 Device addressing is accomplished via three (3) ID pins, 

which  allow  for  a  total  of  eight  (8)  monitors  to  be 

independently addressed on the data bus. 

 

 

3.0    Installation 

 

3.1    Prior to installation, the following items should be considered: 

 

3.1.1  During  the  design  and  layout  of  the  aircraft  cabin,  careful 

consideration of the location of this module is necessary. Some of 

the items to be considered include: 

  Space 

  Available power supply 

  Environmental conditions (temperature, humidity, etc.) 

  Length of cable runs 

 

3.1.2  The  LCDW-9320-101-x  shall  be  installed  to  conform  to  the 

standards  designated  by  the  customer,  installing  agency,  and 

existing conditions as to the unit location and type of installation.  

 

3.1.3  If the adjustment switch (SP-LCD6) is to be mounted in the aircraft, 

the  following  should  be  considered;  the  pigtail  is  24  inches      

(60.96  cm)  in  length  ±1  inch  (2.54  cm)  and  has  6-32  x  0.75  inch 

mounting  studs.  Refer  to  Sections  5.0  and  6.2  for  the  adjustment 

switch characteristics.  

 

3.1.4  An internal cooling fan ventilates internal components and prevents 

undesirable  heat  buildup.  Proper  ventilation  must  be  allowed  for 

when  specifying  the  installation  location. The  closeout area  of  the 

Содержание LCDW-9320-101-X

Страница 1: ...7300 Industry Drive North Little Rock AR 72117 Phone 501 955 2929 Fax 501 955 2988 www decraneaerospace com Installation Manual LCDW 9320 101 x 32 Widescreen LCD Monitor Document 540363...

Страница 2: ...dimensions for SP LCD6 Section 6 2 A1 11 2008 Removed excess mounting information following Section 3 1 6 and corrected reference to 6 0 to 7 0 Section 3 1 6 Corrected grounding lug reference from 6 0...

Страница 3: ...Installation 5 3 2 Unpacking and Inspection 6 3 3 Cautions Warnings 7 3 4 Wiring Requirements 8 3 5 Electrical Characteristics 9 3 6 Mating Connector Information 11 3 7 Pinout Assignment Descriptions...

Страница 4: ...apable of displaying Composite Video SD SDI Video and full color VGA graphics The Composite Input can accept NTSC PAL or SECAM video The VGA input can accept PC graphics with a resolution up to 1280 x...

Страница 5: ...se formats is applied to their respective inputs the monitor will display that format For installations where multiple inputs may be connected and active at the same time the user can set the monitor...

Страница 6: ...for a total of eight 8 monitors to be independently addressed on the data bus 3 0 Installation 3 1 Prior to installation the following items should be considered 3 1 1 During the design and layout of...

Страница 7: ...he left and right sides four 4 on each side The maximum depth should be no more than 1 inch In addition the unit has four 4 8 32 UNF 2B on the back The maximum depth should be no more than 56 inches R...

Страница 8: ...ructions given by the DeCrane Aerospace Audio International representative Refer to the front cover of this manual for address If no return is necessary retain the packing list and the packing materia...

Страница 9: ...ll be in accordance with M22759 or equivalent Protect power wires with circuit breakers or fuses located close to the electrical power source bus 3 4 3 Video Lines Composite Video connections shall be...

Страница 10: ...p HV Up to 1280 x 1024 SXGA resolution Digital Video Format ANSI SMPTE 259M 1997 Operating Temperature 5 to 131 F 15 to 55 C Storage Temperature 4 to 131 F 20 to 55 C 3 5 2 Electrical Specifications S...

Страница 11: ...connector These ID pins allow for up to eight 8 units to be connected on the same DeCrane Aerospace Audio International s proprietary RS 485 data bus while maintaining independent control of each unit...

Страница 12: ...G CONNECTOR LCDW 9320 101 1 DD15M10JVL0 Male Plug or equivalent Positronic Industries LCDW 9320 101 2 DAMA15PK87 Male Plug w male jackscrews or equivalent ITT Cannon 3 7 Pinout Assignment Descriptions...

Страница 13: ...8 Blue Video Ground 9 Key 10 Sync Ground 11 Reserved 12 Reserved 13 Horizontal Sync 14 Vertical Sync 15 Reserved 3 7 2 Wiring description for the SP LCD6 is as follows SP LCD6 Pin Description 1 28 VD...

Страница 14: ...he default factory setting Select either YES or NO 4 SOURCE PRIORITY Selects priority operating mode to PC personal computer or None Setting this mode to PC allows user to normally view Composite Vide...

Страница 15: ...circuitry DeCrane Aerospace Audio International s recommended cleaning method follows A Turn off monitor B Open pre moistened pad and gently wipe evenly across display glass Do not allow solution to p...

Страница 16: ...nality of the unit s 5 3 Troubleshooting Chart Problem Possible Cause Solution Poor picture quality or scrambled video LCD backlight malfunction SP LCD6 programming Poor video source Contact DeCrane A...

Страница 17: ...w unless otherwise specified Weight Approx 0 13 lb 0 06 kg with connector Dimensions l x w x h 2 53 x 1 54 x 2 38 6 43 cm x 3 91 cm x 6 05 cm Note These dimensions are for the cutout 7 0 Reference Dra...

Страница 18: ...DeCrane Aerospace Audio International LCDW 9320 101 x Installation Manual Document 540363 Rev A1 11 2008 Page 17 of 18...

Страница 19: ...al LCDW 9320 101 x Installation Manual Document 540363 Rev A1 11 2008 Page 18 of 18 7 2 SP LCD6 External Menu Switch The following diagrams show the unit dimensions and connector locations for the ext...

Отзывы: