DeCrane Aerospace Audio International, Inc.
LCDP-9084-301-x Installation Manual
Document # 540344, Rev A1, 02/2009
Page 7 of 16
3.3
Cautions and Warnings
3.3.1 It is important to do a pin-to-pin power and ground check on all
connectors. Ensure that power and ground are applied only where
specified. Damage to the unit may result if power or ground is
applied to the wrong points.
3.3.2
DO NOT
connect or disconnect the monitor while power is applied.
3.3.3
DO NOT
remove any factory-installed screws. Damage to the unit
may result and void any warranties.
3.3.4
DO NOT
expose to moisture.
3.3.5
ESD
(Electro Static Discharge) guidelines shall be followed.
3.4
Wiring Requirements
3.4.1 Introduction
The installing agency shall supply and fabricate all external cables
and mating connectors. The length and routing of external cables
should be carefully studied and planned before attempting
installation of the equipment. Allow adequate space for installation
of cable and connectors. Avoid sharp bends and placing cables
near aircraft control cables. Maintain a minimum clearance of three
(3) inches from any control cable. If wiring is run parallel to
combustible fluid or oxygen lines, maintain a separation of six (6)
inches between the lines.
3.4.2 Power Wires
Power and Ground wires shall be in accordance with
M22759
.
Protect power wires with circuit breakers or fuses located close to
the electrical power source bus.