Guide book 

 

mobile lock 

decontamination mobile 

 D 3000 / 4000 / 5000 

 

 
 
 
 

 

 
 
 

Manufacturer :

 

deconta

 

 GmbH 

 

 

Im Geer 20, 46419 Isselburg, Germany 

 

Denomination:

 

decontamination mobile D 3000 / 4000 / 5000

 

 

Type-No. : 

484 

 

Serial-No. : 

………………

 

Содержание decontamination mobile D 3000

Страница 1: ...Guide book mobile lock decontamination mobile D 3000 4000 5000 Manufacturer deconta GmbH Im Geer 20 46419 Isselburg Germany Denomination decontamination mobile D 3000 4000 5000 Type No 484 Serial No...

Страница 2: ...3 3 1 Energy supply 18 3 3 2 Tank filling 18 3 3 3 Room heating 20 3 3 4 Negative pressure plant 20 3 3 5 Shower 21 3 3 6 Sewage water filtering plant 21 3 3 7 Filter change 23 3 3 8 Light 23 3 4 Gas...

Страница 3: ...on in Aluminium Operation limits Dimension type and equipment determine the gross vehicle weight and the coupling load of a trailer at delivery ex works Loading and unloading done by the user change t...

Страница 4: ...blished Has the hand brake been unlocked Have all wheel chocks been removed Have the lights been checked Has the tyre and air pressure been controlled Have all doors been closed and secured Is the roo...

Страница 5: ...sary N B All necessary service work should be carried out by trained personnel in specialist workshops or service stations Please also obey the corresponding guide book of company AL KO Fahrzeugtechni...

Страница 6: ...n bar 195 50 B 10 6 0 The statement of the value of the tyre pressure applies to the cold tyres The trailer is steadily adapted to the newest technical standard It is possible that new tyres sizes are...

Страница 7: ...or the front and back axle of the towing vehicle and may not be exceeded by the trailer 1 6 Coupling Manoeuvre towing vehicle and trailer to the coupling point Do not couple the trailer with overrunni...

Страница 8: ...as firmly reached the soil Push firmly the coupling handle upwards and slacken Raise the drawbar with help of the jockey wheel as far as one can drive away without danger After the uncoupling respect...

Страница 9: ...less steel fresh water tank 230 Volt power supply necessary for operation Diesel Water heating and room heating Warm water heating through 4 kW WEBASTO Diesel warm water producer 220 Liter stainless s...

Страница 10: ...ccurs from the outside via the GEKA connection at the connection fresh water Connect the fresh water hose and open the conduct Switch on the main plug if power supply is connected correctly the contro...

Страница 11: ...rocedure is repeated until the tank has been fully filled Thanks to this way of filling Step by Step you have after a short time tempered shower water at your disposal ATTENTION Never drive the traile...

Страница 12: ...ean area all rooms are ventilated In the dirty area the air is sucked in and blown out through P3 filters Through the fresh air openings the shower and the clean area are also ventilated The fresh air...

Страница 13: ...6 Sewage water filtering plant optional equipment If the switch Sewage water filtering plant is switched on in the technical room the sewage pump starts automatically if you switch the switch shower...

Страница 14: ...d max medium temperature 50 C at 4bar Please note If the switch sewage water filtering plant is not activated no sewage water filtering takes place during the shower procedure The consumed shower wate...

Страница 15: ...er a weekly change by stronger strain a daily change Slacken cap nut Take out the filter and dispose of it Keep filter glas and sealing face clean Insert new filter candles Screw on cap nut with key c...

Страница 16: ...closed Position key switch on Test the green keys of the door case illuminate After 5 Sec s switch to Automatic the forced locking is now activated and the green keys are still glow 3 2 2 Lock system...

Страница 17: ...bin Close the door Shower is activated for a default time of 90 sec After finishing the showering procedure press green key on door case to clean area door can be opened Leave the shower cabin and clo...

Страница 18: ...PORTANT The battery loads only when main switch is turned on 3 3 2 Tank filling In the vehicle there is 220 litres fresh water tank The filling occurs from the outside via the GEKA connection at the c...

Страница 19: ...in the tank is heated up to the chosen temperature When the water in the tank has reached the required temperature fresh water is automatically added If the temperature in the tank drops about 2 C th...

Страница 20: ...out of the dirty area to the clean area all rooms are ventilated In the dirty area the air is sucked in and blown out through P3 filters Through the fresh air openings the shower and the clean area a...

Страница 21: ...t 3 3 6 Sewage water filtering plant optional equipment If the switch Sewage water filtering plant is switched on in the technical room the sewage pump starts automatically if you switch the switch sh...

Страница 22: ...d max medium temperature 50 C at 4bar Please note If the switch sewage water filtering plant is not activated no sewage water filtering takes place during the shower procedure The consumed shower wate...

Страница 23: ...er a weekly change by stronger strain a daily change Slacken cap nut Take out the filter and dispose of it Keep filter glas and sealing face clean Insert new filter candles Screw on cap nut with key c...

Страница 24: ...ted on board battery to make use of all consumers without external power supply When connecting to 230V the battery is automatically reloaded IMPORTANT The battery loads only when main switch is turne...

Страница 25: ...hose into a filled water canister Through activation of the switch Water supply autarkic the water supply is on To keep the pump from running dry it is essential that there is always enough fresh wate...

Страница 26: ...ton for another 10 seconds Please note Firmly secure the gas bottles gas bottles may not be connectiong during a journey close gas bottle during the journey 3 4 5 Negative pressure plant optional equi...

Страница 27: ...owering procedure can be started and stopped by the mixer tap 3 4 7 Sewage water filtering plant optional equipment If the switch Sewage water filtering plant is switched on in the technical room the...

Страница 28: ...max medium temperature 50 C at 4bar Please note If the switch sewage water filtering plant is not activated no sewage water filtering takes place during the shower procedure The consumed shower water...

Страница 29: ...er a weekly change by stronger strain a daily change Slacken cap nut Take out the filter and dispose of it Keep filter glas and sealing face clean Insert new filter candles Screw on cap nut with key c...

Страница 30: ...in soap dish o Dirty room light hooks 230 Volt power socket bench removable floor covering 2 lockers floor drain waste bag holder lockable exterior door boarding aid Plant room light input control Sto...

Страница 31: ...ish Additional chamber Generator room with light and lockable exterior door Roof or side window Negative pressure unit screw filter P3 volume flow 150 m h doors to shower cubicles with self locking ai...

Страница 32: ...Support wheel AU1222 support AU2830 Handle AU457 Registration plate light BE5949 Rear light right AE1833 Rear light left AE1832 Reflector AU2697 Wheel chock AU861 Fixing bracket for wheel chock AU862...

Страница 33: ...ctro Version Spare tyre Option 484010 Fresh water hose BU1504a Sewage water hose BU1504 Car jack Option 484011 Power supply cable BE2264 Hand crank AU988 Wheel key Option 484012 Geka connection Set BO...

Страница 34: ...nection Set BO2266 Geka connection Set BO4616 Fresh water hose BU1504a Sewage water hose BU1504 Spare tyre Option 484010 Car jack Option 484011 Hand crank AU988 Wheel key Option 484012 Diesel jerry ca...

Страница 35: ...e shows Gas Version Pressure regulator AU2963 Lashing strap AU1599 Spare tyre Option 484010 Car jack Option 484011 Adapter AU2962 Power supply cable BE2264 Fresh water hose BU1504a Sewage water hose B...

Страница 36: ...rsion Hand shower AU184 Joint piece AU335 Wall pivot AU334 Shower hose AU957 Soap dish BO5399 O Ring AU197 Filter 1 AU415 Filter 220 AU1153 Cap nut AU252 Filter glas AU256 Filter housing cap AU32 Key...

Страница 37: ...Guide book D 3000 4000 5000 Seite 37 Hooks BO3949 Trash bag BO2711 Filter lid AU1319 Filter P3 AU205 Bench BO5329 stepladder AU2693...

Страница 38: ...Guide book D 3000 4000 5000 Seite 38 6 Technical Data 6 1 Dimensions 2530 3000 6000 4360 6360 3120 6120 2080 2000 Key AU1045 Key Double bit AU389 Breakdown spray AU2745...

Страница 39: ...Guide book D 3000 4000 5000 Seite 39 6 2 Circuit vehicle lighting for all versions identical...

Страница 40: ...ion indicator left yellow 1 5 mm2 2 Rear fog light blue 1 5 mm2 3 Mass contacts 1 8 white 1 5 mm2 4 Direction indicator right green 1 5 mm2 5 Taillight right shape light marker light brown 1 5 mm2 6 B...

Страница 41: ...Guide book D 3000 4000 5000 Seite 41 6 4 Circuits vehicle technology Electric Version...

Страница 42: ...Guide book D 3000 4000 5000 Seite 42...

Страница 43: ...Guide book D 3000 4000 5000 Seite 43 6 5 Circuits vehicle technology Electric Version with forced locking...

Страница 44: ...Guide book D 3000 4000 5000 Seite 44...

Страница 45: ...Guide book D 3000 4000 5000 Seite 45...

Страница 46: ...Guide book D 3000 4000 5000 Seite 46 6 6 Circuits vehicle technology Diesel Version...

Страница 47: ...Guide book D 3000 4000 5000 Seite 47...

Страница 48: ...Guide book D 3000 4000 5000 Seite 48 6 7 Circuits vehicle technology Gas Version...

Страница 49: ...Guide book D 3000 4000 5000 Seite 49...

Страница 50: ...15 16 17 0 10 20 30 40 50 60 70 80 90 100 0 77 0 97 1 22 1 54 1 93 2 44 3 07 3 87 4 87 6 14 7 74 9 75 12 3 15 5 19 5 24 6 30 9 Measuring point Diameter Efficiency 1 0 77 84 3 2 0 97 90 4 3 1 22 93 5...

Страница 51: ...e consumers multiplied by their operation time in hours From the hourly energy needs you can calculate the operation time life of the battery Example Light in operation at the beginning of work at the...

Страница 52: ...mity deconta GmbH Im Geer 20 D 46419 Isselburg Germany Product D 3000 D 4000 D 5000 Type 484 The equipment is constructed in EG Machinery Directive 2006 42 EG accordance with EG Low Voltage Directive...

Отзывы: