POSITIONING  

 

Make sure that your fireplace is installed in a safe place indoors (if you want to use it outdoors, please make 
sure it has been explicitly specified as suitable for outdoors use), which means in a wall made of non-
flammable material with a distance to e.g. curtains of at least one metre (40 in). Also, chose a position for 
your fireplace which is not exposed to any draught, as bioethanol is a volatile fluid. In fact, only the vapour of 
the bioethanol is burning when lit. You should not touch the flames of the lit fireplace or blow into the flames. 
You should also keep a distance of at least 30 cm (12 in) moving past the fireplace, as your movement may 
have an impact on the flames. 
 
The electronics of your custom-made decoflame® fireplace require a connection to a power socket (220-240 
V – 50Hz – 1kW), which ideally should be placed inside the wall cut-out. 
 
NB – We do not recommend to position TV screens or valuable paintings above the fireplace as the upwards 
drifting warm air might damage those. Please do ask us for advise if you still wish to create a setting 
incorporating a TV above the fireplace. 

 

 

 
 

Make sure that the wall cut-out and supports left and right below the base plate of your custom-made 
fireplace are perfectly in level, and all corners of the cut-out are in a perfect 90 degree angle. For all 
dimensions, please refer to the detailed technical drawing for your decoflame

®

 fireplace. 

 
If in doubt, please contact Decoflame. 
 
If your fireplace is installed in a room with a wooden ceiling, you must ensure that the distance between the 
top of the fireplace and the ceiling is at least 1 metre (40 in). It is important that the fireplace is installed 
perfectly in level. When choosing a suitable height as position for your fireplace please also consider keeping 
it out of reach of smaller children and pets. 
 
When lit, the surfaces of the upper part of the fireplace as well as any glass screens will be warm, as the 
heat is led up- and outwards. 
 

Do you have children or pets in the home? If so, make sure an adult keeps an eye on them at all 
times during operation of your fireplace and never leave your fireplace unattended when it is lit.  

 

MAINTENANCE 

 

Before starting to clean the fireplace, make sure it has cooled down and is switched off completely. 
 
Any glass components of your custom-made decoflame

® 

fireplace are made of tempered heat-resistant 

glass. Those glass parts as well as any metal parts which are exposed to the heat of the fire might slightly 
change colour or structure. This is to be considered normal wear and tear and does not constitute a product 
flaw or fault.  
 

Содержание Denver

Страница 1: ...nd Denver with decoflame e ribbon Fire featuring CEVB Technology English Decoflame Aps Stenholm 14 9400 Nørresundby Denmark tel 45 96 30 48 00 info decoflame dk www decoflame com It is imperative that you read this manual before using the fireplace Keep the manual in a safe place for future reference ...

Страница 2: ...NS TABLE OF CONTENT GENERAL SAFETY 2 POSITIONING 3 MAINTENANCE 3 INSTALLATION 4 OPERATING INSTRUCTIONS 6 MESSAGES ON LED DISPLAY AND TROUBLESHOOTING ADVICE 8 SAFETY ADVICE 9 DISPOSAL AND RECYCLING 9 RATING PLATE INFORMATION 9 GENERAL SAFETY Naturally safety is imperative dealing with open fire All decoflame fireplaces are designed manufactured and quality tested in Denmark with highest product saf...

Страница 3: ... your custom made fireplace are perfectly in level and all corners of the cut out are in a perfect 90 degree angle For all dimensions please refer to the detailed technical drawing for your decoflame fireplace If in doubt please contact Decoflame If your fireplace is installed in a room with a wooden ceiling you must ensure that the distance between the top of the fireplace and the ceiling is at l...

Страница 4: ... needs a connection to the mains in order to work Therefore a power socket needs to be present inside the cut out into which the fireplace will be fitted When installing your decoflame built in fireplace you will need Power drill Screwdriver Drill bit suitable for the type of material to which you wish to fix the top and bottom plates of your fireplace Spirit level Tape measure Screws at least Ø 5...

Страница 5: ...e to the highest possible finish All four corners of the cut out must have an exact 90 degree angle Denver drop down e Ribbon Fire The distance between the flame tray and any non flammable material above must not be less than 500mm The distance between the centre of the flame tray and any non flammable material to the back or front must not be less than 150mm DO NOT position the Denver in a draugh...

Страница 6: ...d Use of Remote Control The LED display will always show the following Line 1 Flame level or message e g READY FLAME 3 or FUEL LOW Line 2 Fuel level indicator bar During operation of the fire you could close the pop up lid of the LED display completely by pressing down onto it until you hear a soft click sound You can still use the remote control in order to change the flame level settings or to s...

Страница 7: ...ray is filled with flames depending on the dimensions of the flame tray it might take slightly longer Once the flame tray shows flames throughout its complete width the fire will be burning at a pre set level of 3 as long as the message WARMING UP is shown in the display this pre set level cannot be changed As soon as the warming up phase is finished the message FLAME 3 is shown in the display and...

Страница 8: ...emperature which is too high inside the housing of the e Ribbon Fire Make sure that the ventilation slots around the flame tray are not obstructed do not place ceramic logs or pebbles there Also check that the fireplace has been installed with the necessary 5mm gap all the way around and below the base plate models Montreal and Orlando If you find that all is at it should be call your point of sal...

Страница 9: ... at an adequate level by opening a window or door ever once in awhile during operation of your fire This can be achieved by opening a window for around 5 10 minutes or by leaving doors to adjacent rooms open Should the premises in which the fire is situated be equipped with an MVHR System Mechanical Ventilation with Heat Recovery the room air quality will automatically be kept at a high level and ...

Страница 10: ...10 Decoflame ApS Danmark info decoflame dk tel 45 96 3048 00 For more information please visit www decoflame com or contact Decoflame at info decoflame dk ...

Отзывы: