![Decatur Electronics SI-3C Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/decatur-electronics/si-3c/si-3c_user-manual_2461634023.webp)
SI-3C
™
U
ser
’s M
anual
23
Set target report
Send ASCII T X <CR>
Where ASCII value
X = 0 -> All targets,
X = 1 -> All directional,
X = 2 -> Towards,
X = 3 -> Away
Radar responds back with ASCII “OK” <LF> <CR>
Set horizontal Cosine Angle
Send ASCII H XX <CR>
Where XX = angle degrees in ASCII format
Radar responds back with ASCII “OK” <LF> <CR>
Set vertical Cosine Angle
Send ASCII V XX <CR>
Where XX = angle degrees in ASCII format
Radar responds back with ASCII “OK” <LF> <CR>
Set hold time
Send ASCII h XXXX <CR>
Where XXXX = milliseconds in ASCII format
Radar responds back with ASCII “OK” <LF> <CR>
Set update rate
(note: radar requires a power cycle for new values to be used)
Send ASCII U X <CR>
Where X = 0 -> 1*sec, X = 1 -> 2*sec, X = 2->5*sec, X=3->8*sec,X=4-
>change only, X=5->poll
Radar responds back with ASCII “OK” <LF> <CR>
Set sensitivity
Send ASCII S X <CR>
Where X = Sensitivity in ASCII format (0 to 9 allowed) 9 is
maximum value .
Radar responds back with ASCII “OK” <LF> <CR>