![Debem KM70 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/debem/km70/km70_installation-operating-and-maintenance-manual_2461299018.webp)
18
KM70
ENG_DEBEM S.r.l.
Rev. 01A-EN
01/03/2021
3.4 Receiving
See instructions for inspection at the reception given at the beginning of the manual.
3.5 Storage
In case of storage, the pump must be stored in a covered and dry location, and kept in its original pack-
aging.
The protection caps and lids of the flanges must remain on the pump until it is time for installation. If the
pump will be stored for a long period of time, or stored in particularly severe weather and environmental
conditions, the use of hygroscopic substances (silica gel) or sealing of the package is recommended.
3.6 Return to supplier
Before returning pumps to DEBEM S.r.l., you must ensure the following:
• pump not pressurized,
• pump completely empty,
• electrical connections isolated and motor secured against switch-on,
• pump cooled down,
• auxiliary systems shut down, not pressurized and emptied,
• manometer lines, manometer and fixtures dismounted.
Pumps that have been used for handling toxic or corrosive fluids must be flushed and
cleaned before being returned to the manufacturer.
Always complete and enclose a truthful and full certificate of decontamination when returning to DEBEM
S.r.l. the pump-motor unit or individual parts (see form at the end of manual).
Always indicate any purging and safety measure observed.
Order a safety certificate from DEBEM S.r.l.
if necessary.
Take necessary measures, depending on the required repair work, as listed in the table below when re-
turning the pump to the DEBEM S.r.l.:
Repair carried out
Measure for return
...at the customer's premises
Return the defective component to the
manufacturer.
...at the manufacturer's premises
Flush the pump and decontaminate it if it was
used to pump hazardous media. Return the
complete pump (not disassembled) to the
manufacturer.
...at the manufacturer's premises for warranty
repairs
Only in the event of hazardous pumped media:
flush and decontaminate the pump. Return the
complete pump (not disassembled) to the
manufacturer.
Содержание KM70
Страница 2: ......
Страница 37: ...DEBEM SRL Via del Bosco 41 21052 Busto Arsizio VA ITALY www debem com MOM_KM70_REV 01A EN ...