background image

            Dean , 8700 Line Avenue, Shreveport, Louisiana 71135

TEL  1-318-865-1711                    FAX  (Parts) 1-318-219-7140                 (Tech Support) 1-318-219-7135

Price: $6.00

PRINTED IN THE UNITED STATES

SERVICE HOTLINE

1-800-551-8633

819-5709  04-99

Содержание Electric Fryer

Страница 1: ...ial Food Equipment Service Association recommends using CFESA Certified Technicians Price 6 00 24 Hour Service Hotline 1 800 551 8633 819 5709 04 99 Super Runner 38 Series Electric Fryers CE Installat...

Страница 2: ...STALLATION INSTALLATION MUST BE PLANNED IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL ELECTRICAL CODE NFPA 70 1984 OR LATEST EDITIONS WARNI...

Страница 3: ...ver of this booklet To speed up your order the following information is required Model Number Serial Number Type of Voltage Item Part Number Quantity Needed 1 2 SERVICE INFORMATION Call the Dean Facto...

Страница 4: ...ermostat The temperature control is mounted in the cabinet behind the front door on the bottom left side of the cabinet d AUTOMATIC SAFETY FEATURE High temperature detection to shut off electric heate...

Страница 5: ...e all accessories from the carton Do not discard or misplace these as they will be needed After unpacking immediately check the equipment for visible signs of shipping damage If such damage has occurr...

Страница 6: ...asters are installed to ensure the fryer is level before using b Leg Installation 1 Remove unit from pallet 2 Carefully raise unit with forklift pallet jack or other steady means 3 Insert hex head bol...

Страница 7: ...m 1 1 16 open end wrench by turning the hex bullet on the bottom of the leg See figure 3 2 on page 7 3 The hex bullet is for minor leg height adjustment only Do not adjust more than 22mm 1 4 When leve...

Страница 8: ...f installation to ensure it meets the intent of these instructions The on site supervisor and or operator s should be made aware that there is a restraint on the appliance and if disconnection of the...

Страница 9: ...that the heaters and thermostat operate properly drain the vessel of water and dry thoroughly Refill fry vessel with shortening as directed in section 3 6 Final Preparation 3 6 FINAL PREPARATION a Whe...

Страница 10: ...L POWER SERVICE IS DISRUPTED FOR MORE THAN A FEW SECONDS TURN FRYER OFF THIS WILL PREVENT THE FRYER FROM ACCIDENTALLY HEATING OIL WHEN POWER SERVICE IS RESUMED WARNING IF USING SOLID SHORTENING NEVER...

Страница 11: ...he food being prepared minimizes flavors being transferred from batch to batch and increases frying compound lifespan Filter the frying compound at least once daily or more frequently if cooking is he...

Страница 12: ...oth front casters locking mechanisms have to be turned OFF To return the unit to its previous installed position see sections 3 4 and 5 3 of this manual 5 4 WEEKLY a Completely drain the oil from the...

Страница 13: ...ned for this material at the end of each day a Do not use steel wool abrasive cloths cleansers or powders b Do not use a metal knife spatula or any other metal tool to scrape stainless steel Scratches...

Страница 14: ...operating position It should be clamped to the 2nd element with 1 5 mm 1 16 inch spacing See Figure 6 2 2 Place the sensing bulb of a high quality immersion thermometer about 38 mm 1 1 2 inches above...

Страница 15: ...P N 1549 BLK 2 WHT 2 PURP RED Oper Thermostat P N 2557 Hi Limit P N 2687 PURP RED BLU YEL WHT 2 BLK 2 YEL BRN Transformer P N 807 1999 240V 24V YEL YEL BLU BRN Power Switch SPST P N 807 2196 YEL K2 K1...

Страница 16: ...2686 CASTER RIGID 3 44 1363 NIPPLE DRAIN EXT 1 1 4 12183 2 DOOR ASSY SS SR38 12 0308 2 DOOR PANEL SS SR38 12 0097 DOOR PIN 1503 MAGNETIC DOOR CATCH 4 1039 2 HANDLE CHROME DOOR 5 9002949 SHIM CASTER 6...

Страница 17: ...E 25 12185 1 VESSEL MS WELD ASSY SR38E 14 0592 8 HEAT ELEMENT 220V 4000W 380 400 415 240 USA 14 3KW 26 14 0592 7 HEAT ELEMENT 208V 4666W USA 14KW 1902 O RING SEAL 4 EA ELEMENT 14 0695 O RING RETAINER...

Страница 18: ...le lines up to drain Solid shortening will solidify as it cools and clog the lines 9 2 FILTER PREPARATION a Turn the fryer OFF b Remove the filter pan cover c Remove the crumb screen if provided and c...

Страница 19: ...y under the fryer s drain valve a Open the drain valve by pulling the handle out The oil will transfer from the fryer vessel to the filter pan b Turn the filter switch to the ON position on the filter...

Страница 20: ...op of the new sheet It is essential that two sheets of Dean filter papers are used use of other than OEM parts will void the filter warranty g Replace the hold down ring and latch into position Sprink...

Страница 21: ...the flex hose valve Go to page 22 Yes No Yes No No it Yes Yes No Insert flexible oil return hose into the filter pan holster Turn pump motor ON Disconnect flexible oil return hose Make sure it is coo...

Страница 22: ...rs by latching the hold down ring Sprinkle 45kg 16oz of filter powder evenly across the surface of the filter paper Check the filter sump Sediment collects around the suction pipe in the filter bottom...

Страница 23: ...ntinue Pump motor is clogged or faulty Contact your local Factory Authorized Service Center Check filter circuit breaker Push the circuit breaker reset button Verify power cord is connected to the out...

Страница 24: ...in hot water until you can blow through it The line is clear Reconnect hose to the pump inlet Does oil flow Conduct normal filter operations There may be a plug in the bottom of the filter pan Take f...

Страница 25: ...n 8700 Line Avenue Shreveport Louisiana 71135 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 Tech Support 1 318 219 7135 Price 6 00 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 819 5709 04...

Отзывы: