G E K O
EN
21
OPERATING PARAMETERS
Operators speed adjustment during the stroke while opening
30%tot........................100%tot
Operators speed adjustment during the stroke while closing
30%tot........................100%tot
Operators speed adjustment during slow
-down while opening and closing
15%tot........................100%tot
Slow down duration adjustment while opening
5%tot............................75%to
Slow down duration adjustment while closing
5%tot............................75%tot
Operator 1 force adjustment while opening
(if = 100% obstacle detection deactivated)
10%tot…...........................50%tot
Operator n.1 force adjustment while closing
(if = 100% obstacle detection deactivated)
10%tot…...........................50%tot
Operator n.2 force adjustment while opening
(if = 100% obstacle detection deactivated)
10%tot…...........................50%tot
Operator n.2 force adjustment while closing
(if = 100% obstacle detection deactivated)
10%tot…...........................50%tot
Automatic closing times adjustment
(if = 0 automatic closing deactivated)
0sec...................................255sec
Pedestrian automatic closing time adjustment
(se = 0 pedestrian automatic closing deactivated)
0sec...................................255sec
Pedestrian stroke duration adjustment
5%tot…...........................100%tot
Pre
-flashing time adjustment
0sec…….10sec
Adjustment of phase displacement time while opening
0sec……………30sec
Adjustment of phase displacement time while closing
0sec……………30sec
Collectivity function: if it is activated it deactivates both opening and closing inputs for the whole duration of automatic opening and closing
•
000:
“collectivity
function
”
deactivated
•
001:
“collectivity
function
”
activated
Ram blow function: it pushes the motors closed for one second before each opening movement, so as to ease the electric-lock release
•
000:
“
ram
blow
”
deactivated
•
001:
“
ram
blow
function
”
activated
“Reversal”
mode selection
(during the manoeuvre a command impulse
reverse
the mouvement)
or “step by step
” (during the manoeuvre a command impulse
stops
the mouvement). A next impulse restart the operator to the opposite direction.
•
000:
“
reversal
function
”
•
001:
“step
by
step
function
”
PHO
TO
input
functioning:
if=0
photocells
are
enabled
while
closing
and
at
start
when
gate
is
closed;
if=1
photocells
are
always
enabled;
if=2
photocells
are
enabled
while
closing
only
.
When
enabled,
its
activation
provokes:
the
inversion
(while
closing),
the
stop
(while
opening)
and
prevent
the
starting
(when
gate
is
closed).
•
000:
photocells
enabled
while
closing
and
at
gate
closed
•
001:
photocells
always
enabled
•
002:
photocells
enabled
only
while
closing
Selection
of
functioning
mode
:
“warning
light
”
(output
is
ON
at
gate
opened,
OFF
at
the
end
of
the
closing
manoeuvre)
or
“courtesy
light
”
(output
is
ON
during
every mouvement, OFF when the operator stops according to a pre
-settable delay
.
•
000:
“warning
light
”
•
>000
:
“courtesy
light
”
off
delay
(1sec………………255sec)
Searches for end of stroke while opening too: when activated, operators stop only at their arrival et the end of stroke, also while opening
.
•
000:
Stop
when
opening
on
a
memorized
point
•
001:
Stop
when
opening
on
the
end
of
stroke
“soft start
” function: motors accelerate gradually until they reach the set speed, avoiding sudden departures
•
000:
“soft
start
”
deactivated
•
001:
“soft
start
”
activated
Lenght
adjustment
of
reversal
on
obstacle:
if=0
it
executes
a
complete
reversal,
if>
0
indicates
the
duration
(in
seconds)
of
the
stroke
after
inversion
caused
by
the
detection of an obstacle during opening
.
•
000:
complete
reversal
on
obstacle
•
>000:
duration
of
reversal
on
obstacle
(1sec……………..10sec)
Lenght
adjustment
of
reversal
on
obstacle:
if=0
it
executes
a
complete
reversal,
if>
0
indicates
the
duration
(in
seconds)
of
the
stroke
after
inversion
caused
by
the
detection of an obstacle during closing
.
•
000:
complete
reversal
on
obstacle
•
>000:
duration
of
reversal
on
obstacle
(1sec……………..10sec)
Facilitation
manual
release:
If≠0,
after
detecting
the
locking
stop,
the
engine
reverses
for
a
brief
time
to
release
the
pressure
on
it,
and
thus
facilitate
the
manual
release. The set value shows the length of the inversion. If=0 function disabled
•
000:
facilitating
release
disabled
•
>000:
facilitation
activated
with
release
time
equal
to:
(1x25ms……………..10x25ms)
Unused parameter
Unused parameter
Unused parameter
Unused parameter
Содержание GEKO