5.3 Advanced programming
Here are some added programming procedures relating to remotes memory management and advanced configuration of the
control inputs.
1
Deletion of memorized transmitters
1.1 Deletion of all transmitters
1. Scroll down the parameters until you visualize P004;
2. Confirm by pressing on the key;
3. When “
” is flashing, press the
key for a few
seconds;
4. Release the key as soon as “
” stops flashing;
5. All memorized transmitters have been deleted (display
shows again P004).
1.2 How to search and delete a transmitter
1. Scroll down the parameters until you visualize P006;
2. Confirm by pressing on the key;
3. By pressing on
and
, keys, select the transmitter
you want to delete (eg.
);
4. When “
” flashes, confirm the deletion by pressing
the key for a few seconds;
5. Release the key when appears “
”;
6. The selected transmitter is deleted (display shows again
P006).
2
Inputs configuration
Where the installation requires different commands and / or additional
to the standard ones described by plans on page 22, you can configure
each input for the operation desired (eg START, PHOTOS, STOP, etc ...).
1. Scroll down the parameters with the
and
to see that corre-
sponding to the desired one:
●
P010=for INPUT 1;
●
P011=for INPUT 2;
●
P012=for INPUT 3;
●
P013=for INPUT 4;
●
P014=for INPUT 5;
2. Confirm by pressing on the key to get access to the parameter
(eg. P012);
3. Scroll down with the and , keys to set the value corresponding
to the desired operation (refer to table “Input Configuration para-
meters”
on page 20
);
4. Confirm by pressing on the key (display shows again P012).
5. Execute the new connection to the input just reconfigured.
6 UNLOCKING AND MANUAL OPERATION
In the event of malfunctions or simple power failure, release the motor (Pic. 9) and perform the operation manually.
The knowledge of the unlocking device is very important because, in times of emergency, lack of speed in operating this device can
cause danger.
WARNING
The efficancy and safety of manual operation of the automation is guaranteed by
DEA
System only if the installation
has been installed correctly and with original accessories.
7 START-UP
The start-up phase is very important to ensure maximum security and compliance to regulations, including all the requirements of
EN 12445 standard which establishes the test methods for testing the automation for gates.