C1000 Series Service & Maintenance Manual

Service and Repair

SECTION IV

A.  Electrical Components

1.  Pressure Switch: Turns on or off the power supplied to the 
individual compressor motor switches. The pressure switch is preset 
to run the compressors to 100psi and then open, therefore stopping 
the motor(s). When the system pressure drops to 80psi, the switch 
closes, running the compressor motors to 100psi again. 

To test the switch, bleed all pressure from the tank. Remove the 
pressure switch top cover with a 3/8” wrench. With an AC voltmeter, 
place the test leads on the outer terminals as shown in Fig. I.  The 
voltage indicated should agree with the machine data plate, either 115 
or 230 volt AC. If no voltage is present, check the circuit breaker.

Fig. I

Fig. J

ELECTRICAL

If the proper voltage is present on the outer terminals, move the voltmeter test leads to the inner terminals of the pressure switch as shown in 
Fig. J.  If NO voltage is present, the pressure switch is defective. If voltage is present, proceed to the next step.

Turn the machine power on, and wait for compressor to reach 100psi 
and stop running. The 3/8” adjusting screw may be turned clockwise 
to increase the cutoff pressure or counter-clockwise to decrease the 
cutoff pressure. The maximum pressure cutoff should not exceed 
100psi. If the compressor will not cut off at the desired preset 
pressure, or will not stop under any condition, the pressure switch is 
defective.

w w w.dcionline.com

12

Содержание C1103

Страница 1: ...D C1203 D C2106 D C2206 D C3210 C Series COMPRESSOR Copyright 2006 DCI All Rights Reserved D C1103 D C1203 D C2106 D C2206 D C3210 C Series COMPRESSOR Compressor Service Maintenance Manual 92311 Rev...

Страница 2: ...1 www dcionline com www dcionline com...

Страница 3: ...SERVICE REPAIR INSTRUCTIONS A Troubleshooting Chart B Electrical 1 Replacing Pressure Switch 2 Replacing Power Switch 3 Replacing Compressor Head 4 Replacing Time Operated Purge Valve C Pneumatic 1 Re...

Страница 4: ...service procedures before attempting to service this machine Our unique dryer purge system operates much differently than conventional air compressors Understanding the proper operation and design wil...

Страница 5: ...ons 1 Single 1 horsepower compressor head on 20 gal Horizontal tank See Fig A 2 Dual 1 horsepower compressor heads on 20 gal Horizontal tank See Fig B 3 Dual 1 horsepower heads on 30 gal horizontal ta...

Страница 6: ...5 C1203 3 95 1 20 34 24 29 5 230 6 7 10 C2106 7 95 2 20 34 24 29 5 115 26 8 30 C2206 7 95 2 20 34 24 29 5 230 13 4 15 C3210 11 85 3 30 46 26 36 230 21 1 30 NOTE ALL VOLTAGES ARE 5 MODEL NUMBER MAXIMUM...

Страница 7: ...ttom of the filter bowl The compressed air also travels through the coalescing filter element which removes 99 998 of all particles down to 0 01 microns A filter change indicator located on the top of...

Страница 8: ...e compressor cycles off C The Left timer knob on the purge valve controls the duration of the purge cycles This timer is factory preset and should not be adjusted The factory setting is at the maximum...

Страница 9: ...C1000 Series Service Maintenance Manual Theory of Oporation Theory of Operation THEORY OF OPERATION While Not Running Electrical Schematic SECTION II 1 800 624 2793 7...

Страница 10: ...e element first turn off the compressor motor switches Then turn off the Dryer bypass valve as shown in Fig E With dryer bypass valve in OFF position press the TEST button on the time operated purge v...

Страница 11: ...floor Check the filter screen inside the filter strainer valve as shown in Fig G If the strainer shutoff valve is on and the screen is not clogged replace the Time Operated Purge Valve with DCI part N...

Страница 12: ...breaker Ensure that supply voltage matches equipment ratings Check for loose wiring Check contact points and adjust or replace Bleed pressure from system to ensure proper starting Ensure supply volta...

Страница 13: ...or replace intake filter element Clean Replace valve plate Air leaks compressor too small to meet demand Add ventilation and or cooling to equipment room Clean or replace solenoid valve assembly Left...

Страница 14: ...oltage indicated should agree with the machine data plate either 115 or 230 volt AC If no voltage is present check the circuit breaker Fig I Fig J ELECTRICAL If the proper voltage is present on the ou...

Страница 15: ...on up position check for voltage to the compressor motor as shown in Fig K If the proper voltage is present the power switch is good If no voltage is present at the motor replace the corresponding po...

Страница 16: ...embly 2 Turn OFF the strainer shutoff valve in Fig N 3 Remove the valve and replace with DCI Part Number 2011 for 230 volt machines OR DCI Part Number 2848 for 115 volt models 4 Return the strainer sh...

Страница 17: ...Replace the differential filter indicator by unscrewing the entire assembly counterclockwise with a 15 16 6 point box end wrench Install the new indicator in the reverse order 3 Automatic Filter Float...

Страница 18: ...er 2006 Coalescing Element 2135 Check Valve 2135 Check Valve 2014 Drying Chamber Assembly Pressure Gauge 2011 Automatic Purge Valve 230 Volt OR 2848 Automatic Puge Valve 115 Volt 2009 Strainer Shut Of...

Страница 19: ...C1000 Series Service Maintenance Manual Illustrated Parts Breakdown SECTION V Unpacking Electrical Schematic 1 800 624 2793 17...

Страница 20: ...ION V Unpacking Plumbing Schematic Left Motor Right Motor Check Valve Check Valve Aftercooling Tubing Coalescing Filter Condensate Drain Drying Chamber Flow Check Drying System Pressure Gauge Dryer By...

Страница 21: ...1 800 624 2793 19...

Страница 22: ...305 N Springbrook Road Newberg Oregon 97132 USA 503 538 8343 800 624 2793 www dcionline com...

Отзывы: