PSXX Manual Rev: A             Software Rev: F 

 

times every foot. You can make your own twisted pair wire by placing two ends of the 

wire in a drill bit, chuck the drill tight, and then turn on while you or something else 

holds the other end 
 

***

PSXX LED Outputs do not require resistors***

 

E. Terminal Wiring Descriptions 

J1 Input Power Connector 

 

J1-1        DCC Power Input 1 [from DCC Booster]

  

 

J1-2        DCC Power Input 2 [from DCC Booster]

 

 

J1-3        Connect to next PSXX J1-1 [Power Link]

 

 

J1-4        Connect to next PSXX J1-2 [Power Link]

 

J2 Output Power Connector 

 

J2-1        Switched DCC Power Output 1 [to track/bus]

 

 

J2-2        DCC Power Output 2 [to track/bus]                                          

 

JP1 Program Jumper 

 

JP1-1 & JP1-2 Place jumper on pins 1 & 2 for Programming

 

 

JP1-2 & JP1-3 Place jumper on pins 2 & 3 for Operations

 

J4 Block Occupancy 

 

J4-1       Input Manual OFF + 

 

J4-2       GND Manual OFF - 

 

J4-3       Output Block Shorted Emitter 

 

J4-4       Output Block Shorted Collector 

 

J4-5       Output Block Occupied Emitter 

 

J4-6       Output Block Occupied Collector 

J5 Status Outputs [Remote]  

 

J5-1       +Remote D17 (RED) Anode 

 

J5-2       - Remote D17 (RED) Cathode 

 

J5-3       + Input Photocell  

 

J5-4       - GND Photocell  

J6 Trip Current Settings by Jumpers 

 

Set trip current using either Jumpers or CV 49: NOT BOTH 

 

No Jumpers = 2.0 amperes [default] 

 

J6-1 to J6-2 = 1.0 amperes 

 

J6-3 to J6-4 = 3.0 amperes 

 

If both jumpers are installed [J61-J62 & J63-J64], the current limit is set to 4.0 amperes. 

 

 

 

 

***

PSXX LED Outputs do not require resistors*** 

 

 

 

Содержание PS 1 Series

Страница 1: ...t of years of research into problems dealing with false overloads that cause premature shut down of DCC Boosters and other Circuit Breakers These false overloads are caused by large capacitors used in...

Страница 2: ...lied to the layout the PSXX can be set to always turn on always remain off power on as needed by DCC command or to use the power status present when the layout was last shut down Outputs for LED Indic...

Страница 3: ...t 1 All connections involve two wire inputs from the DCC Booster or Main DCC Power Bus into a PSXX and two wire Outputs to the isolated track block 2 All PSXX circuit breakers are ready to operate wit...

Страница 4: ...On Main functions D12 Green LED On indicates DCC power J1 input D7 Green LED On indicates DCC power J2 output D17 Red LED On D7 Green OFF indicates short circuit D18 Blue LED indicates that current li...

Страница 5: ...ng more than one PSXX PSXX 2 PSXX 3 insure all input output polarities are the same 3 If you are using a heavier bus wire such as 10 AWG solder a short length of 12 or 14 AWG wire to your heavier bus...

Страница 6: ...the PSXX by sending an accessory ON command check your system manual for correct key sequence to accessory address 2042 Refer to CV68 for address limitations c With the Manual Reset jumper in place yo...

Страница 7: ...some or all of these trains have more than one locomotive you could have 10 to 15 current drawing units all competing for power in a fairly small area Assuming all the locomotives have efficient moto...

Страница 8: ...s is how each district is used In a yard area for example there is a higher risk of derailments occurring with their associated shorts You might want to isolate this area into a separate district so t...

Страница 9: ...er Output 2 to track bus JP1 Program Jumper JP1 1 JP1 2 Place jumper on pins 1 2 for Programming JP1 2 JP1 3 Place jumper on pins 2 3 for Operations J4 Block Occupancy J4 1 Input Manual OFF J4 2 GND M...

Страница 10: ...pen the switch to reset the PSXX or send an accessory ON command to the PSXX on off command address see Section B item 11 J7 5 TBD J7 6 GND J10 DCC Power In Remote LED Indicator Output J10 1 Remote D1...

Страница 11: ...LED The LED is connected directly to the terminals J5 1 and J5 2 have resistors installed on the board that limit the current to about 5mA 780 ohms No resistor is required The remote LED will duplica...

Страница 12: ...Accessory Addresses See Section K DCC System Sequential Programming Instructions for Setting Address and Programming CV s The easiest way to address a PSXX circuit breaker is at your workbench The PSX...

Страница 13: ...econd address and issue an ON or OFF command 9 Repeat for the third address you want to use 10 Each time you press the ON or OFF key with a new address you should see D17 flash indicating that the PSX...

Страница 14: ...he track and the train can be moved Since the photocell is now disarmed you can move the train over the cell without affecting the power status For all systems whenever you enter an address or CV valu...

Страница 15: ...unction requires an address 7 Enter the CV number followed by the value The small red LED D17 on the PSXX will blink each time a command is accepted and the CV value is stored correctly in the CV 8 If...

Страница 16: ...the solid state switch which allows this connection to be open or closed OFF or ON CV53 Enable Block Current Auto Calibration Default 0 no calibration CV53 66 enables Block Current Auto Calibration th...

Страница 17: ...es The CV63 default is 0 Setting CV63 42 will not change the CV value but it will reset the PSXX CV66 controls how the PSXX outputs power to the track when the associated booster is turned on Default...

Страница 18: ...the Block Occupied output will flash whenever the photocell is armed The PSXX power output is on The flashing can be inhibited by setting CV67 1 Any other value of CV67 will enable the flashing CV67 d...

Страница 19: ...n accessory address you can easily get a feel for the timing involved 5 In normal operating mode not programming mode select an accessory address that has not been programmed into the PSXX 6 Send an a...

Страница 20: ...WCH key and switch addresses Digitrax Programming PSXX CVs Using DT400 402 500 Do Setting Addresses First 1 Disconnect PSXX from DCC power 2 Move PSXX JP1 Jumper to Program Position Pins 1 2 3 Turn DC...

Страница 21: ...rogram Position Pins 1 2 3 Turn DCC power on 4 Select a locomotive number with the keypad that is unused on your layout 5 Press the F keys and the or key to select POM mode then hit Enter 6 Press or u...

Страница 22: ...osition Pins 1 2 3 Turn DCC Power on 4 Use SELECT LOCO to address an unused locomotive number 5 Press PROG ESC key to enter PROGRAM ON MAIN mode 6 Press ENTER to select any unused locomotive number 7...

Страница 23: ...rogram Position Pins 1 2 3 Turn DCC Power on 4 Press LOCO to address an unused locomotive number 5 Press PROG key to enter PROG MAIN TRACK mode 6 Press ENTER 7 Continue to press ENTER until CV is in t...

Отзывы: