DCC Specialties PS 1 Series Скачать руководство пользователя страница 11

PSXX Manual Rev: A             Software Rev: F 

11 

 

J2

 – DCC track power output terminal from the PSXX circuit breaker to the track. 

JP1

 – Programming & Operation jumper. Normal operating configuration is when the 

jumper is in the JP1-2 to JP1-3 position. Place the jumper in the JP1-1 to JP1-2 position 

to enter programming mode. 

J4-1 and J4-2

 

are the inputs for the photocell detector used for the stopping function 

and/or the block occupancy function. Note:  

  Be sure there is sufficient light above the cell to trigger the circuit.  

  You can use a white LED to illuminate the photocell.  

  Whenever you arm the photocell, it assumes it is uncovered and adjusts its 

sensitivity to the current lighting conditions.  

  It is sensitive across the light spectrum. White will be best.  

  The photocell sensitivity is calibrated to the local light intensity each time the 

photocell is armed.  

  You can order the photocell sensor through Tony’s Train Exchange. 

J4-3 [-] and J4-4 [+]

 

are connected together [up to 5 mA] when the breaker has detected 

a short circuit and open during normal operation. This is an optically isolated open 

collector transistor and provides no power. 

J4-5 [-] and J4-6 [+]

 

are open if the block is not occupied and are connected together 

[up to 5 mA] if the block is occupied. This is an optically isolated open collector transistor 

and provides no power. 

J5-1 [+] and J5-2 [-]

 

are for a remote status LED. The LED is connected directly to the 

terminals. J5-1 and J5-2 have resistors installed on the board that limit the current to 

about 5mA (780 ohms)No resistor is required. The remote LED will duplicate the state 

of D6. 

J5-3 [+] and J5-4 [-]

 

are for network power status reporting. They are connected 

together [up to 5 mA] when the PSXX output switch is ON. This is an optically isolated 

open collector transistor and provides no power. 

J6

 

– Sets the current trip level. When CV49=00 [default] the trip current is 2.0 amperes 

if no jumpers are installed. This is the correct setting for the NCE Power Cab. If J6-2 is 

connected to J6-1 and J6-4 to J6-3 is open, then the current trip is 1.0 amperes. If J6-4 

is connected to J6-3 and J6-2 to J6-1 is open, then the current trip is 3.0 amperes. If J6-

4 is connected to J6-3 and J6-2 is connected to J6-1, then the current trip is 4.0 amperes. 

J7-1 and J7-2

 

are available for powering external LEDs, etc in conjunction with Block 

Occupied or Block Shorted outputs. Maximum load should be less than 25mA. J7-1 is 

the 5v output and J7-2 is the GND Return connection for the J7-1 5V output 

J7-4 to J7-3

 

are the auto/manual reset inputs. If the connections are open, the breaker 

will automatically try to reset every two seconds [default]. If the terminals are connected 

together with a SPST toggle switch or N/C push button switch, then the breaker will 

remain off after a short until the connection from J7-1 to J7-2 is momentarily opened or 

an accessory ON command is sent to the PSXX on-off accessory address [see Section 

B item 13]. 

Содержание PS 1 Series

Страница 1: ...t of years of research into problems dealing with false overloads that cause premature shut down of DCC Boosters and other Circuit Breakers These false overloads are caused by large capacitors used in...

Страница 2: ...lied to the layout the PSXX can be set to always turn on always remain off power on as needed by DCC command or to use the power status present when the layout was last shut down Outputs for LED Indic...

Страница 3: ...t 1 All connections involve two wire inputs from the DCC Booster or Main DCC Power Bus into a PSXX and two wire Outputs to the isolated track block 2 All PSXX circuit breakers are ready to operate wit...

Страница 4: ...On Main functions D12 Green LED On indicates DCC power J1 input D7 Green LED On indicates DCC power J2 output D17 Red LED On D7 Green OFF indicates short circuit D18 Blue LED indicates that current li...

Страница 5: ...ng more than one PSXX PSXX 2 PSXX 3 insure all input output polarities are the same 3 If you are using a heavier bus wire such as 10 AWG solder a short length of 12 or 14 AWG wire to your heavier bus...

Страница 6: ...the PSXX by sending an accessory ON command check your system manual for correct key sequence to accessory address 2042 Refer to CV68 for address limitations c With the Manual Reset jumper in place yo...

Страница 7: ...some or all of these trains have more than one locomotive you could have 10 to 15 current drawing units all competing for power in a fairly small area Assuming all the locomotives have efficient moto...

Страница 8: ...s is how each district is used In a yard area for example there is a higher risk of derailments occurring with their associated shorts You might want to isolate this area into a separate district so t...

Страница 9: ...er Output 2 to track bus JP1 Program Jumper JP1 1 JP1 2 Place jumper on pins 1 2 for Programming JP1 2 JP1 3 Place jumper on pins 2 3 for Operations J4 Block Occupancy J4 1 Input Manual OFF J4 2 GND M...

Страница 10: ...pen the switch to reset the PSXX or send an accessory ON command to the PSXX on off command address see Section B item 11 J7 5 TBD J7 6 GND J10 DCC Power In Remote LED Indicator Output J10 1 Remote D1...

Страница 11: ...LED The LED is connected directly to the terminals J5 1 and J5 2 have resistors installed on the board that limit the current to about 5mA 780 ohms No resistor is required The remote LED will duplica...

Страница 12: ...Accessory Addresses See Section K DCC System Sequential Programming Instructions for Setting Address and Programming CV s The easiest way to address a PSXX circuit breaker is at your workbench The PSX...

Страница 13: ...econd address and issue an ON or OFF command 9 Repeat for the third address you want to use 10 Each time you press the ON or OFF key with a new address you should see D17 flash indicating that the PSX...

Страница 14: ...he track and the train can be moved Since the photocell is now disarmed you can move the train over the cell without affecting the power status For all systems whenever you enter an address or CV valu...

Страница 15: ...unction requires an address 7 Enter the CV number followed by the value The small red LED D17 on the PSXX will blink each time a command is accepted and the CV value is stored correctly in the CV 8 If...

Страница 16: ...the solid state switch which allows this connection to be open or closed OFF or ON CV53 Enable Block Current Auto Calibration Default 0 no calibration CV53 66 enables Block Current Auto Calibration th...

Страница 17: ...es The CV63 default is 0 Setting CV63 42 will not change the CV value but it will reset the PSXX CV66 controls how the PSXX outputs power to the track when the associated booster is turned on Default...

Страница 18: ...the Block Occupied output will flash whenever the photocell is armed The PSXX power output is on The flashing can be inhibited by setting CV67 1 Any other value of CV67 will enable the flashing CV67 d...

Страница 19: ...n accessory address you can easily get a feel for the timing involved 5 In normal operating mode not programming mode select an accessory address that has not been programmed into the PSXX 6 Send an a...

Страница 20: ...WCH key and switch addresses Digitrax Programming PSXX CVs Using DT400 402 500 Do Setting Addresses First 1 Disconnect PSXX from DCC power 2 Move PSXX JP1 Jumper to Program Position Pins 1 2 3 Turn DC...

Страница 21: ...rogram Position Pins 1 2 3 Turn DCC power on 4 Select a locomotive number with the keypad that is unused on your layout 5 Press the F keys and the or key to select POM mode then hit Enter 6 Press or u...

Страница 22: ...osition Pins 1 2 3 Turn DCC Power on 4 Use SELECT LOCO to address an unused locomotive number 5 Press PROG ESC key to enter PROGRAM ON MAIN mode 6 Press ENTER to select any unused locomotive number 7...

Страница 23: ...rogram Position Pins 1 2 3 Turn DCC Power on 4 Press LOCO to address an unused locomotive number 5 Press PROG key to enter PROG MAIN TRACK mode 6 Press ENTER 7 Continue to press ENTER until CV is in t...

Отзывы: