ZonePro™ User Manual
48
Appendix
ZonePro
™
Zone Controller Wiring
The Zone Controllers, (ZC-1, ZC-2, ZC-3, ZC-4) can be wired serially or in parallel. To wire in
series each Zone Controller must have an identification or zone number chosen using the DIP
switches on the side of the controller (see diagram A). Each controller must have a unique
number chosen although there may be multiple Zone Controllers controlling a single zone, or
a single Zone Controller that controls multiple outputs. The Zone Controllers can then be wired
together and connected to the ZonePro units (see diagram B).
The Zone Controllers may also be wired in parallel with the use of the ZC-BOB. To wire in
parallel (home run cabling), each controller must have a unique identification or number cho-
sen using the DIP switches on the rear of the panel (see diagram A). To wire in parallel, each
controller must be wired into a port of the ZC-BOB with a connecting wire going to the
ZonePro units (see diagram C).
Zone Controller Installation
The installation of the Zone Controllers MUST be accomplished with the use of cable which is
rated VW-1 or higher. Common NEC designations which meet this rating include: CMP, CMR,
CMG, CM and CMX.
ZC-1 -
The ZC-1 is a programmable zone controller that allows volume level control from
a wall panel.
ZC-2 -
The ZC-2 is a programmable zone controller that allows volume level and mute control
from a wall panel.
ZC-3 -
The ZC-3 allows wall panel program selection for the ZonePro units.
ZC-4 -
The ZC-4 provides contact closure program selection for room combining or fire
safety applications applications.
ZC-Fire -
The ZC-Fire is the interface to generic fire alarm relays. When fire alarm acti-
vates, the general purpose relay can typically be programmed to close if normally open or
vices-versa. The ZC-fire interface unit monitors the state of the relay (n.o. or n.c.) and upon
the state of change, notifies the Zone pro, which then mutes its outputs.
ZC-6 -
The ZC-6 is an up and down controller. Because the ZC-6 uses momentary switch-
es, it does not override the ZonePro’s implantation of scheduled scene changes. The poten-
tionmeters used in ZC2 and ZC2 would override such a pre-scheduled scene change.
ZC-7 -
The ZC-7 is used for momentary Mic Zone select.
ZC-8 -
The ZC-8 is used for a combination of volume up/down, and four position
source/program select.
ZC-BOB -
The ZC-BOB allows parallel or home run cabling of the Zone Controllers.
A.5 - Zone Controller Wiring and Install
Содержание Zone Pro 640
Страница 1: ...User Manual 640 641 ...
Страница 5: ...INTRO CUSTOMER SERVICE INFO Defining the ZonePro WARRANTY INFO INTRODUCTION 640 641 ...
Страница 9: ... Getting Started Section 1 ZonePro ...
Страница 13: ...SOFTWARE OPERATION Section 2 ZonePro ...
Страница 17: ...SYSTEM SETUP Setup Section 3 ZonePro ...
Страница 24: ...System Setup 16 Section 3 ZonePro ZonePro User Manual ...
Страница 25: ...DETAILED PARAMETERS Detailed Parameters Section 4 ZonePro ...
Страница 41: ...APPLICATION GUIDE Section 5 ZonePro ...
Страница 42: ...Application Guide 34 SECTION 5 ZonePro ZonePro User Manual 5 1 Retail Install ...
Страница 44: ...Application Guide 36 SECTION 5 ZonePro ZonePro User Manual 5 2 Restaurant Bar Install ...
Страница 46: ...Application Guide ZonePro User Manual 38 Section 5 ZonePro 5 3 Health Club Install ...
Страница 48: ...Application Guide ZonePro User Manual 40 Section 5 ZonePro 5 3 Night Club Install ...
Страница 50: ......
Страница 51: ... Appendix ZonePro ...