Figure 9.
PG cable type 2 (SX), PG power management (in the center), PG power supply (DX).
The shielded bipolar cable must be connected to the terminal blocks circled in red in figure 10. The two
cables are interchangeable. Before reaching the two terminal blocks, the bipolar cable must be unsheathed
and positioned in the earth terminal circled in yellow. It is important that the cable is properly stripped and
that the shielding is well in contact with the earth terminal.
Figure 10
. Power management wiring
Once the electrical connection is complete, the current can be adjusted. Using the current selector indicated
in figure 7, select the charging power available at the meter to which the DazeBox has been connected. The
number zero "0" refers to a dip switch positioned downwards (referring to figure 7), while the number one
"1" refers to a dip switch positioned upwards. The possible combinations and the relative reference powers
are indicated in table 6.2
15