Reservoir Breather Cap for Pump on units that are shipped assembled and filled with

 fluid. 

 

 

With the jack installed in the vertical position, remove the

 f

lush

 m

ounted

 f

ill

 p

lug from the top of the 

reservoir and discard. Replace with

 b

reather

 c

ap. Failure to do so will cause the jack to 

operate erratically. 

 

Operation 

 

 

To raise and lower the jack, simply push and hold the rocker switch in the up or down position. The 
jack will hold a position by releasing the switch at any time. There is no need to take the weight off 
the jack when storing the trailer, as the positive check valves in the system will not allow the jack to 
bleed down. 

 

*Note: When the jack is fully retracted, the fluid level in the reservoir should be approximately one 

inch below the fill cap. If fluid needs to be added, use Dexron III automatic transmission fluid (the 
same as used for a GM automobile). 

 

 Caution

 

 

 

 

The keyed switch must be in the off position and the key must be removed when the jack is not in 
use and/or when the trailer is in transit. If unit is not supplied with a keyed switch, the +12v 
battery lead must be fed through a power disconnect switch to fully isolate the system during 
inactivity or travel. The minimum switch rating must be 100 ampere DC. 

 

With any hydraulic application, holding any position on a cylinder must be done with safety in 
mind. Failure in the system may cause the jack to retract or extend on its own. When working 
under or near the trailer, always use jack stand of appropriate rating to support the weight of the 
trailer. 
 

Manual Override 

– Hand Pump - Pump # 2142 & 3126, 3170 

 

The following procedure gives step-by-step instructions on how to operate the manual override to 
either extend or retract the jacks. 
Your AM series Single Leg Jack is available with a Manual Override, depending on the specific 
unit ordered.

 If your unit is equipped with the Override Hand Pump, it is operated as follows: 

To

 Extend

 your Jack: 

1. Install a handle in the hand pump. Pump the handle to extend the jack. You may have to 

pump 10-20 times before you build enough pressure and the jack begins to extend. 

To

 Retract

 your Jack: 

1. Locate the red knurled knob on the directional valve. Pull it out and turn ¼   turn. The knob 

will remain in the “out” position. Do not use anything other than your fingers to manually 
shift the directional valve. 

2. Install a handle in the hand pump. Pump the handle to retract the jack. You may have to 

pump 10-20 times before you build enough pressure and the jack begins to retract. Return 
the directional valve to the normal position.  

Caution: Following manual override operation, failure to return all valves to normal position  
may result in one or more jacks drifting down from their retracted (stowed) position. For 
directional valves, rotate the red knob until it “snaps” back to the normal position.

Содержание EQUALIZER SYSTEMS AM Series

Страница 1: ...Loom clips to secure switch and harness to the trailer Self tapping screws or pop rivets to secure loom clips Wire tie Jack Your AM Jack may have been provided with a mounting flange or bracket depen...

Страница 2: ...Lead 12volts Attach a 4 gauge wire between the positive 12V terminal on the battery and the large post on the solenoid opposite the black motor wire on the solenoid If circuit protection is required...

Страница 3: ...must be done with safety in mind Failure in the system may cause the jack to retract or extend on its own When working under or near the trailer always use jack stand of appropriate rating to support...

Страница 4: ...eal from the top of the motor Place the drill with the proper size hex bit on the manual override shaft located at the top of the motor Run drill in a clockwise direction at 2000 rpm minimum The jack...

Страница 5: ...only run in the extend direction if the battery does not have enough capacity to operate the motor and shift the directional valve I push the switch and nothing happens Ensure both positive and negat...

Страница 6: ...Assembly Wiring Pump s 2390 2532 Solenoid Wiring Bi Rot Pump s 2390 2532 2542 Wiring for Pump 3040 3041 3200 3201 and 3201KS...

Страница 7: ...ut exception Time associated with learning about the repair or excessive diagnostic and installation time will not be reimbursed Warranty labor will be reimbursed at the authorized service center s pu...

Отзывы: