4
6
The Flow Switch and Cell are to be fitted into the return line as the last pieces
of equipment the water passes through before returning to the pool: i.e
always after the pump, filter, heater (if applicable), etc. If a heater is present,
all equipment must be at a minimum distance away, according to the heater
manufacturer’s recommendations (see Fig 2).
Lay out the equipment to ensure there is enough pipe space available.
Ÿ
When positioning the Flow Switch, ensure at least 30cm of straight pipe
before the Flow Switch. If installed after the Electrolytic Cell, the Cell
provides this space. The raised arrow on the black plastic cap must be
pointed in the direction of water flow as it returns to the pool. If installed
horizontally, ensure that the wire-side faces upwards. The Flow Switch is
approximately 100mm in length; a typical gap required is 30mm.
Ÿ
When positioning the Cell, consider the side of the cell with the cord as
the "inlet" side. If installed horizontally, ensure that the wire- side faces
upwards. From end to end, the Cell with both unions is approximately
40cms length; a typical gap required is 35cms.
To ensure proper operation, verify that the arrow on the
flow switch (located on the side) points in the same
direction of water flow
.
CAUTION
Flow Switch
Double-check that all Cell and Flow Switch cables can
reach the Control Panel.
CAUTION
For installation with 1 ½” plumbing, use 2” to 1 ½”
reducer bush with flow switch, and use alternate 1 ½”
Cell Unions; be sure to note any new or additional
measurements before cutting pipe.
CAUTION
3
1
Water Flow
Fig 2
2
Ensure that the pool pump and all AC power is turned
off before installation.
CAUTION