Fig. 3 Pump Axis Limits

6

5.  INSTALLATION

i)    Pump Application

Ÿ

A wide range of pump models are available and the pump selected must be 
matched to the borehole output to provide optimal operating performance. This 
should be done with reference to the borehole drillers report in consultation with 
a borehole installation specialist. As a rule pump output should not exceed 65% 
of maximum tested borehole yield.

Ÿ

Minimum Borehole Diameter 3”pumps -100mm, 4”pumps-110mm, 6”pumps-
160mm, DS30-200mm.

Ÿ

Maximum Pump Immersion Depth - 200m for DSP, 250m for DS and 35m for 
D3SP.

Ÿ

Pumped liquid should be clean, thin and non-explosive containing no solid 3 
particles or fibres. Sand content should not exceed 50gm/m or else pump life 
will be reduced and any warranties will be invalidated.

0

Ÿ

Liquid  temperature  should  not  exceed  40 C  in  order  to  preserve  rubber 
components. Also for high temperatures one motor size larger should be fitted to 
prolong  motor  life  due  to  high  operating 
temperatures.

Ÿ

Pumps  can  be  installed  either  vertically  or 
horizontally, though if installed horizontally the 
discharge  outlet  should  never  fall  below  the 
horizontal plane. For all horizontal installations 
a flow sleeve should be used and also there 
should  be  a  minimum  of  0.5m  water  depth 
above the pump to prevent the formation of a 
vortex.

Содержание DS

Страница 1: ...Installation Operating Manual DS DSP D3SP Submersible Borehole Pumps...

Страница 2: ...otors Three Phase Motors 4 INSTALLATION Pump Application Pump Position Pump Lowering 5 PUMP OPERATION 6 MAINTENANCE 7 TROUBLE SHOOTING 8 WARRANTY 9 2 DELIVERY STORAGE Delivery Storage Handling 1 1 2 2...

Страница 3: ...sheet which will be supplied with the pump DAYLIFF D3SP pumps are compact 3 diameter submersible multistage centrifugal pumps specifically designed for small scale water supplies from boreholes and we...

Страница 4: ...ii Motor All pumps are fitted with sealed liquid cooled oil filled 2 pole asynchronous squirrel cage motors constructed principally of stainless steel Single phase motors require purpose designed con...

Страница 5: ...t Leakage at this joint will cause motor failure Care must be taken when fitting the motor tail cable to the motor The connection between the tail cable and the motor should be lubricated with a non c...

Страница 6: ...in the form of an MCB or fuse Coarse current rating should be approx 3X maximum rated motor current For all three phase motors and single phase motors above 1 1kW a DOL starter is required Note that...

Страница 7: ...entification of the start run and common windings is essential or else the motor will burn out Extra care must therefore be taken when connecting and if in doubt the pump supplier should be consulted...

Страница 8: ...and 35m for D3SP Pumped liquid should be clean thin and non explosive containing no solid 3 particles or fibres Sand content should not exceed 50gm m or else pump life will be reduced and any warrant...

Страница 9: ...ecommended that the complete pump is submerged at least 3m the dynamic water level and if possible the pump should be installed at least 3m from the bottom of the borehole to prevent silting damage As...

Страница 10: ...o approximately 1 3 of its maximum volume of water Observe if there are impurities in the water and then gradually open the valve until the water is observed to be clear If the water continues to be s...

Страница 11: ...e Fault Finding Guide Also important is a periodic check of motor winding and insulating resistance especially if there is an abnormal operating current or voltage reading For three phase motors windi...

Страница 12: ...al call service technician Motor starter contactor defective Repair the motor starter contactor The control circuit has been interrupted or is defective Check the electric installation No electricity...

Страница 13: ...the strainer Replace or repair the pump The valves in the discharge pipes are partly closed or blocked Check and clean or replace the valves and discharge pipe Wrong direction of rotation Change direc...

Страница 14: ...lve changed Pull out the pump and clean or replace the non return valve The non return valve is leaking or stuck half open Long period until water flow after start Increase the installation depth of t...

Страница 15: ...warranty condition or liability implied by law the liability of Davis Shirtliff hereafter called the Company in respect of any defect or failure of equipment supplied is limited to making good by rep...

Страница 16: ...INS 278C 08 18...