Gas Valve
Technical Specifications
PARAMETER VALUE
Maximum connection pressure. Pa (mbar)
Gas pressure control range in front of the nozzle. Pa (mbar)
Minimum adjustable gas flow.
m³/h
Minimum gas pressure drop between inlet and outlet. Pa (mbar)
Power source. V
Current frequency. Hz
Valve design.
Valve opening time. Second
Valve closing time. Second
Connection thread for inlet and outlet gas pipelines.
Permissible ambient air temperature. °C
Weight. kg
Rough dimensions. Length x Width x Height mm
600 (60)
500 ... 5000 (5...50)
0,3
400 (4)
230
1
Normal closed.
50
0,7
-15...+60
G3/4’’
1
115 x 65 x 93
Ignition Electrode
Technical Specifications
PARAMETER VALUE
Power source. V
Current frequency. Hz
Consumed electrical power.
(Excluding the power of the connected valve block.)
V
The strength of the connected valve block. VA (Max.)
The strength of the connected valve block. V
Supply current frequency of the connected valve block. Hz
Waiting time for the ignition system. Second
Response time of the flame control system. Second
Distance between spark plug electrodes. mm
Precision of combustion control automation.
µ
A
Ambient temperature. °C
Mounting position.
Weight. kg
230
1
50
230
100
15
50
0,5
4
±
1
1
0,15
At the bottom of the boiler.
-15...+60
8