Turn on the gas supply and power supply to the appliance.
»
Make sure that the inlet pressure of the gas valve is at least 21 mbar.
»
Loosen the screw at the gas outlet pressure measurement point on the gas
valve of the device.
»
Connect the manometer to the nipple using a rubber or PVC pipe.
»
Measure the gas outlet pressure of the valve block.
»
Pressure adjustment of the 1st stage with a Phillips screwdriver at the point
shown in Figure 1. The pressure is increased by turning it clockwise, and the
pressure is decreased by turning it counterclockwise.
»
Pressure adjustment of the largest stage is ten bites from the place shown in
Figure 1. It is increased by turning it clockwise with the wrench, by turning it
counterclockwise is reduced.
»
By slowly turning the screw of the adjustment pressure regulator to the
right and left, the burner nozzle. Make sure that the gas pressure at the inlet
changes.
»
After the gas pressure adjustment is made, disconnect the manometer from
the nipple.
»
Be sure to tighten the screw inside the nipple well.
»
After tightening the screw, check the tightness with a soapy solution.
Gas Valve
Setting Procedure
DSR SERIES PARTS
Front panel
Back panel
Motherboard box
Stainless wire homogeneous
Aluminum cutter side
Boiler (empty)
Cauldron (with stones)
Electrical wiring assembly
C-14 socket
Glass fuse
Power cord
Motherboard
Stainless logo
Motherboard label
Injector
Sheath
Gas seal 3/4
Gas injector nut
Gas flex
Tors screw
Wall mount
Lighter
Gas valve
Touch-up paint (1 can)
Mounting pins (With Nuts)
Remote control