52
Excessive Noise
Check if the appliance is
securely positioned.
Place the appliance on horizontal
and firm ground.
Check if any loose, vibrating
parts.
Secure and tight the parts.
Noise sounds like water
flowing.
Noise comes from flowing
refrigerant. This is normal.
Error code E0
Communication faults
between main PCB and
display PCB.
Check the wire harness of the
display PCB for damage.
Error code E1
Ambient temperature sensor
failure
Check connection or replace it. To
clean or replace the temperature
sensor.
Error code E2
Coil temperature sensor
failures.
Check connection or replace it. To
clean or replace the temperature
sensor.
Error code Ft
Condensate water high level
alarm.
Empty the drain pan by removal the
rubber plug.
Long term storage
If you will not be using the appliance for
an extended period of time (more than a
few weeks) it is best to clean the appliance
and dry it out completely. Please store the
appliance per the following steps:
1. Unplug the appliance and remove
exhaust hose and window kit store with
the appliance.
2. Drain the remaining water from the
appliance.
3. Clean the filter and let the filter dry
completely in a shaded area.
4. Collect the power cord at the water tank.
5. Re-install the filter at its position.
6. The appliance must be kept in upright
position when in storage.
7. Preserving the machine in ventilating,
dry, non- corrosive gas and safe place
indoor.
Attention!
The evaporator inside the machine has to
be dried out before the appliance is packed
to avoid component damage and molds.
Unplug the appliance and place it in a dry
open area for days to dry it out. Another way
to dry the appliance is to set the humidity
point more than 5% higher than the
ambient humidity to force the fan to dry the
evaporator for a couple of hours.
Disposal
WARNING! Releasing refrigerant into
atmosphere is strictly forbidden!
o Below mentioned SVHC substances are
present in parts of the article in amounts
> 0,1 %:
• Short chain chlorinated paraffins
• DEHP