34
CHAPTER 5.
USAGE
Table 5.5.: Remote reset and power button effects
Button
Description
Reset
Pressing this button is similar to pressing the reset button di-
rectly on the remote system (see Figure
5.14
on the page before).
Be aware that pressing the reset button will result in uncondi-
tional and immediate cold start of the system. This might dam-
age open files and the file system itself.
Power (short press)
A short press on the ATX button is normally caught by the
running operating system that tries to initiate a controlled shut-
down.
Usually this should always be the first action you try in case you
would like to power off your system. Only in case this is not
working you should try the long press button.
Please note that after you have pressed this button the power
state displayed in the administration panel won’t immediately
reflect the requested change. A controlled shut down of the sys-
tem may take up to some minutes. You can observe the action
caused by your button press using the Remote Console window
or by reloading the Server Power Control panel.
Power (long press)
This will unconditionally power off the system. Even if you have
submitted a short press before, this will shut down the power
supply of the host system.
The effect of the long button press can be immediately observed
on the panel that is loaded into the browser because of the button
press. The power state will be off.
Reset/Power Button Press Durations:
These options allow changing the duration for pressing the reset or ATX power button. The values
are the time in milliseconds the reset/power button will remain pressed. The default value should
work in almost all cases, so you should keep it unchanged. However there are some systems, which
specify other values. Please consult those system’s manuals and change the settings accordingly.
Additionally ATX distinguishes between two different durations. The shorter duration is meant for
initiating a controlled operating system shutdown. The longer duration is an unconditional power
off.
These settings only apply to the internal LARA power option.
Figure 5.16.: Power Control settings
Содержание LARA
Страница 1: ...LARA Installation and User Guide...
Страница 4: ...iv...
Страница 8: ...viii Contents...
Страница 12: ...xii List of Tables B 1 LARA Video Modes 67 C 1 Key Names 69...
Страница 30: ...18 CHAPTER 4 CONFIGURATION...
Страница 74: ...62 CHAPTER 5 USAGE...
Страница 76: ...64 CHAPTER 6 FREQUENTLY ASKED QUESTIONS...
Страница 78: ...66 APPENDIX A GLOSSARY...
Страница 80: ...68 APPENDIX B LARA VIDEO MODES...
Страница 86: ...74 APPENDIX D PIN ASSIGNMENTS...