&KHFNWKHEDVHPDFKLQHRSHUDWLQJSUHVVXUHDQGÀRZUDWH,IWKHSUHV
sure output of the excavator is too low the EMV will not run at all. This
LVEHFDXVHWKHVHTXHQFHYDOYHSUHVVXUHVHWWLQJKDVWREHRYHUFRPH
before oil can pass to the drive motor.
&KHFNWKHVHTXHQFHYDOYHVHWWLQJE\LQVWDOOLQJDSUHVVXUHWHVWJDXJHLQ
the clamp close line and monitoring the pressure at which the valve
opens. Ensure this is set to 165 bar.
'DPDJHGVHTXHQFHYDOYH±UHPRYHDQGLQVSHFWEXWUHSODFHLILQGRXEW
using
new
seals.
7.2.4 Motor failure or gearbox problem. Try connecting the two main oil
supply lines directly to the hydraulic motor ports and running the unit
ZLWKORZHQJLQHVSHHG±HIIHFWLYHO\ORZRLOÀRZUDWH&DXWLRQLWZLOOEH
HDV\WRRYHUVSHHGWKHPRWRULQWKLVFDVHEHFDXVHWKHÀRZUHJXODWRULV
now out of the circuit.
7.2.5 If the unit does not vibrate either the motor has become damaged or
there is a fault with the gearbox. Check the oil level in the gearbox
WRVHHWKDWLWKDVQRWEHFRPH¿OOHGZLWKK\GUDXOLFRLOIURPWKHPRWRU
shaft seal – in this case the unit usually runs very slowly unless metal
fragments have become entrapped in the transmission system as a
result.
7.2.6 Remove the motor from the gearbox and test.
7.2.7 As a last resort take the saddle assembly off the EMV and remove
the gearbox lid for an internal inspection. The gears, shafts and
bearings should rotate freely. Caution - pay attention to trapping body
parts in the mechanism during inspection!
7.2.8 Consult the manufacturer from section 7.2.5 onwards.
7.3.1 Check that the base machine hydraulic output complies with the
PLQLPXPVSHFL¿HGIRUWKHXQLW6SHFL¿FDOO\FKHFNZLWKWKHH[FDYDWRU
supplier/manufacturer what system pressure is available on the bucket
ram circuit at 90 l/min.
&KHFNWKHVHWWLQJRIWKHÀRZUHJXODWRUWRHQVXUHDGHTXDWHÀRZLV
reaching the drive motor.
&KHFNWKHVHTXHQFHYDOYHSUHVVXUHVHWWLQJ±VHHVHFWLRQ,IWKLV
setting is too close to the operating pressure the EMV will speed up then
slow down, speed up then slow down etc.
7.3.4 Check the gearbox oil level. If it is much higher than the sight glass the
motor shaft seal has probably blown – see section 7.4.
7.2
EMV CLAMP CLOSES
BUT THE UNIT WILL NOT
VIBRATE
7.3
UNIT WILL NOT RUN AT
THE CORRECT SPEED
- “JUMPS AROUND” OR
SPEED FLUCTUATES
Содержание EMV-220 METRIC
Страница 2: ......
Страница 4: ......
Страница 6: ...GENERAL NOTES www dcpuk com...
Страница 28: ...8 0 HYDRAULIC METRIC HOSE KIT PART No 220 000 00 00 Serial no 220 025 onwards...
Страница 29: ...16 8 7 17 19 18 4 1 2 3 10 11 10 9 6 22 20 5 15 14 11 17 12 12 21 12 12 17...
Страница 31: ...9 0 PARTS LISTS FOR THE EMV220 PART No 220 000 00 00 Serial no 220 025 onwards...
Страница 38: ......
Страница 40: ......
Страница 45: ......
Страница 50: ...STAND Remarks Inspect general condition of stand...