23
Step 3 - Check for Leaks
Make sure the inlet water supply pressure is 140kPa (20psi) Min and 1000 kPa (150psi) Max.
Open valve in water line. Turn faucet on (hold if necessary) to fill tank (about 1 minute). When tank is full, water will flow
from faucet. Allow water to flow from the faucet for approximately 10 seconds. Turn faucet off. Check for leaks.
Step 4 - Prepare for Power
Double check thermostat control dial is turned fully counterclockwise to its lowest setting. Thermostat control dial
controls the water temperature, not the water flow or delivery.
IMPORTANT INFORMATION
- This dispenser is equipped with a Self Re-setting Thermal Fuse
Turn thermostat to lowest setting and fill tank with water before plugging the power cord from the tank into an electrical
outlet.
If tank is empty and the thermostat set in the low setting position (approximately at the 11:00) when the power cord is
connected, the self re-setting fuse in the heater control will disconnect the current to the heater after approximately one
minute, thus protecting the heater from a "dry start" failure. The fuse in the heater control will self-reset after
approximately 30 minutes.* Turn on the water supply to the tank and continue the installation.
Continued misuse will cause damage to the appliance and is detectable thus, voiding the warranty.
"(Re-setting of fuse can be accelerated by turning on the water supply and dispensing water until fuse re-sets in
approximately 3 minutes.)
Step 5 - Test Installation
For electrical connection, please refer to Electrical Supply section on page 2.
Turn thermostat control dial clockwise to the maximum position. Maximum temperature will be reached in about 15
minutes and dispenser will be ready for use. Lower the temperature setting by turning thermostat control dial
counterclockwise if you notice vapor or a boiling noise.
To raise or lower the water temperature, rotate the thermostat dial. With the dial set at a low setting (the dial pointing at
approximately 11:00), the water temperature will be approximately 140
゚
F (60
゚
C). When the dial is set at the maximum
setting (dial turned fully clockwise), the water temperature will be approximately 203
゚
F (95
゚
C).