daviteq WSSFC-V1A-025 Скачать руководство пользователя страница 8

277

115

3

16

1

TX_POWER

 

20

int16

Read/Write

RF Tx
power

278

116

3

16

2

CONSTANT_A

 

1

float

Read/Write

Constant a
for scaling
measured
value

306

132

3

16

1

ENB_DATGRAM

 

1

uint16

Read/Write

bit0:
enable
datagram
0
bit1:
enable
datagram
1
bit2:
enable
datagram
2

307

133

3

16

1

TEMPERATURE_OFFSET_X10

 

0

int16

Read/Write

Offset
adjustment
for
measured
temperature
value

Please refer to 

this link.

Please refer to the detailed specifications in 

this link.

For warranty terms and support procedures, please refer t

this link.

Use-cases:

Case studies:

White-papers:

END.

 

Revision #8 
Created Wed, Sep 7, 2022 9:48 AM  by 

Lộc Vĩnh Nguyễn

 

Updated Thu, Sep 8, 2022 10:06 AM  by 

Phan Van Luc

3.3 Calibration for Sigfox-Ready V1A Vibration Sensor

4. Product specification 

5. Warranty and Support 

6. References

Содержание WSSFC-V1A-025

Страница 1: ...ct Type 2 parts Mounting Type Direct process mounting for sensor wall mount for transmitter Powered by 2 x AA batteries 1 5V Information Changes in this version v s previous version Item Changes Changed by Changed Date Approved by Approved Date 1 Initial version D Q Tuan 29 08 2022 N V Loc 05 09 2022 To use this product please refer step by step to the below instructions Operating Principle Uplink...

Страница 2: ...llow the Sigfox back end system can send the downlink message for changing the configuration of the sensor Please refer to the downlink section for more details The uplink payload will tell the user the HW version FW version and current configuration of the device Case 5 During commissioning testing or calibration sensor the user can force the device to send the uplink message to get the data imme...

Страница 3: ...ey 01 x Wall mounting bracket and screws 01 x Vibration sensor module V1A 1 3 Quick Test Step 1 Prepare the values of communication settings Note All Sigfox sensors are pre configured with the correct RC before delivery The settings of Device ID Device PAC and RC could also be read from the device memory map Please reference section 3 2 Sensor configuration for details Step 2 Add the device to Sig...

Страница 4: ...s transmitter must be mounted at the minimum level of 2m from the ground for a better RF signal To get the strongest RF signal please follow this link How to mount it with a mounting bracket please checkthis guide Insert the batteries into the wireless transmitter and check the system to see whether the wireless transmitter already sent the first message to the system Please follow this link to le...

Страница 5: ...oot the sensor part Maintenance works Yes No Descriptions Consumable parts replacement Yes The battery is the only part need to check the lifetime to replace Check the battery status on the back end system Cleaning device No Re calibration Re validation No No calibration is required for the wireless transmitter Please refer to this link 1 5 3 Device calibration configuration 2 Maintenance 2 1 Trou...

Страница 6: ...r tothis link for a complete understanding of this measuring technique Below are some important configuration parameters which affect the operation of the device like battery life measurement accuracy and alert threshold For Battery life estimation please refer to this link measure_period Default 3600s This is the time period for the wireless transmitter to wake up and take the measurement from th...

Страница 7: ...rameters of the device Read only Parameter Table Modbus Register Decimal Modbus Register Hex Function Code Read No of Registers Description Range Format Property Comment 2 2 3 4 FW_VERSION string Read 6 6 3 2 HW_VERSION string Read 8 8 3 2 DEVICE_ID hex Read Product ID 10 A 3 4 DEVICE_PAC hex Read Product PAC 14 E 3 1 SENSOR_TYPE 1 255 uint16 Read Sensor or Input Type Read Write Parameter Table Mo...

Страница 8: ...SET_X10 0 int16 Read Write Offset adjustment for measured temperature value Please refer to this link Please refer to the detailed specifications inthis link For warranty terms and support procedures please refer tothis link Use cases Case studies White papers END Revision 8 Created Wed Sep 7 2022 9 48 AM by Lộc Vĩnh Nguyễn Updated Thu Sep 8 2022 10 06 AM by Phan Van Luc 3 3 Calibration for Sigfox...