Step
Discription
Note
1
Remove fuel: Remove all fuel from the tank.
Some tank have been welded with oil filter and
have float level sensor installed, so it is
necessary to take out the float level sensor
before removing the fuel.
2
Clean the tank
Must clean the tank thoroughly.
3
Central hole locating: The hole will be in the
center of tank's up-per side or closest to
center.
This is an important step as it will directly
affect the stability of the fuel level data.
4
Drilling the central hole:
After determining the center of the oil
tank, we clean the surface and use a 38
mm drill to make a hole on the oil tank.
Remove any burrs from the drilled hole
by a file.
Before drilling, it is vital to check whether the
hole is affected by the internal metal frame or
obstacles at the bottom the tank.
5
Flange installation:
Place the 4 mm rubber gasket at the
center of the tank's upper side.
Place the plastic flange onto the rubber
gasket (4 mm).
Mark 4 points at the bolt hole.
Use screws /rivets to fasten the 4 mm
rubber gasket and the plastic flange
onto tank.
Only using screws for the thick and hard
tanks.
Unplug the screw/ rivet symmetrically.
8. Sensor Installation Guidance