background image

Step

Discription

Note

1

Remove fuel: Remove all fuel from the tank.

Some tank have been welded with oil filter and
have float level sensor installed, so it is
necessary to take out the float level sensor
before removing the fuel.

2

Clean the tank

Must clean the tank thoroughly.

3

Central hole locating: The hole will be in the
center of tank's up-per side or closest to
center.

This is an important step as it will directly
affect the stability of the fuel level data.

4

Drilling the central hole:

After determining the center of the oil
tank, we clean the surface and use a 38
mm drill to make a hole on the oil tank.
Remove any burrs from the drilled hole
by a file.

Before drilling, it is vital to check whether the
hole is affected by the internal metal frame or
obstacles at the bottom the tank.

5

Flange installation:

Place the 4 mm rubber gasket at the
center of the tank's upper side.
Place the plastic flange onto the rubber
gasket (4 mm).
Mark 4 points at the bolt hole.
Use screws /rivets to fasten the 4 mm
rubber gasket and the plastic flange
onto tank.

Only using screws for the thick and hard
tanks.
Unplug the screw/ rivet symmetrically.

8. Sensor Installation Guidance

Содержание CAP10G

Страница 1: ...ication according to EN61236 1 standard The technicians who install sensor must be graduated from college of mechanic or electric The mechanical installation staff drill cut grind etc must have skills...

Страница 2: ...astic flange onto tank for all type of tanks and only using screws for the thick and hard ones Sensor length Standard 700mm 1000mm optional 1200 or 1500mm Cuttable down to 200mm Longer than 1500mm sug...

Страница 3: ...ers In case of using stainless steel rivet 12 Twist drill 4 mm In case of using stainless steel rivet 04 Tube cutter 13 Electrical tape 05 Swivel Blade 14 Cutting pliers 06 Hacksaw 15 Phillips screwdr...

Страница 4: ...tral hole After determining the center of the oil tank we clean the surface and use a 38 mm drill to make a hole on the oil tank Remove any burrs from the drilled hole by a file Before drilling it is...

Страница 5: ...L Original length of the sensor H Height of the tank Example Sensor length is L 2000 H 1700 mm C 326 mm Cut the sensor pipe length of 326 mm 7 Calibration After cutting make sure the sensor tube is cl...

Страница 6: ...over the sensor and then use plastic and then use plastic twister seal to lock the head seal and connector seal to protect the sensor Please follow the below steps Note Step 1 Remove the cover Step 2...

Страница 7: ...fore installation to avoid confusing White PWR 8 50VDC Blue PWR OVDC Black Resistive Output 240 33 Ohm Recommend to use 24VDC power The signal cable from sensor should be protected by corrugated hose...

Страница 8: ...s Solutions 1 No output Sensor s powering wire is damaged Check out on the sensor s powering wire Overpowering has burnt the signal cable and circuit board Send to manufacturer Being tampered Check th...

Страница 9: ...efects from the manufacturer depending on the actual situation Daviteq will consider replacement or repairs Notes One way was shipping cost to the warranty centre shall be paid by Customers 1 The warr...

Страница 10: ...Nam Hung Vuong Res An Lac Ward Binh Tan Dist Ho Chi Minh City Vietnam Tel 84 28 6268 2523 4 ext 122 Email info daviteq com www daviteq com Revision 2 Created Fri Oct 16 2020 6 19 AM by Ki t Anh Nguy...

Отзывы: