Specifications

 (See www.davisinstruments.com for more information)

Operating Temperature . . . . . . . . . . . . . . . . . 32° to +140°F; 0° to +60°C
Current Draw . . . . . . . . . . . . . . . . . . . . . . . . . Average: 100 mA; Peak 700mA
Housing Material . . . . . . . . . . . . . . . . . . . . . . Rugged ABS Plastic
Backup Batteries . . . . . . . . . . . . . . . . . . . . . . 4 AA (not included)
Battery Life  . . . . . . . . . . . . . . . . . . . . . . . . . . 5 days

AC Adapter  . . . . . . . . . . . . . . . . . . . . . . . . . . 5 VDC, 1000 mA

Wi-Fi Frequency Range & Power  . . . . . . . . . 2412-2472 MHz, 802.11b/g/n; less than 72mW
BLE Frequency Range & Power . . . . . . . . . . 2402-2480 MHz, less than 1mW

Sensor Data (internal sensors)
   Barometric Pressure

Resolution and Units  . . . . . . . . . . . . . . . 0.01" Hg, 0.1 mm, 0.1 hPa, 0.1mb. (user selectable)
Range. . . . . . . . . . . . . . . . . . . . . . . . . . . 16.00" to 32.50" Hg, 410 to 820 mm Hg, 

540 to 1100 hPa or mb

Elevation Range. . . . . . . . . . . . . . . . . . .  -1500' to +15,300' (-460 m to 4670 m)
Update Interval  . . . . . . . . . . . . . . . . . . . 1 minute

Inside Relative Humidity

Resolution and Units  . . . . . . . . . . . . . . . 0.1%
Range & Accuracy . . . . . . . . . . . . . . . . . 1 to 100% RH; ±2%

Accuracy. . . . . . . . . . . . . . . . . . . . . . . . . ±2%

Update Interval. . . . . . . . . . . . . . . . . . . . 1 minute

Inside Temperature

Resolution and Units  . . . . . . . . . . . . . . . Current Data: 0.1°
Range. . . . . . . . . . . . . . . . . . . . . . . . . . . +32° to +140°F (0° to +60°C)
Sensor Accuracy. . . . . . . . . . . . . . . . . . . ±0.5°F (±0.3°C) (typical)
Update Interval  . . . . . . . . . . . . . . . . . . . 1 minute

Weather Station Wireless Communications

ID Codes Available  . . . . . . . . . . . . . . . . 8
Range

Line-of-Sight . . . . . . . . . . . . . . . . . . .  up to 1000 feet (300 m)
Through Walls  . . . . . . . . . . . . . . . . . 200 to 400 feet (60 to 120 m)

Receive Frequency

 (abridged list)

US. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 902.0 - 928.0 MHz FHSS
EU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 868.0 - 868.6 MHz FHSS

Australia, Brazil  . . . . . . . . . . . . . . . . . . 918.0 - 926.0 MHz FHSS

India . . . . . . . . . . . . . . . . . . . . . . . . . . . 865.0 - 867.0 MHz FHSS
Japan . . . . . . . . . . . . . . . . . . . . . . . . . . 928.15 - 929.65 MHz FHSS
New Zealand, Peru  . . . . . . . . . . . . . . . 921.0 - 928.0 MHz FHSS
Pakistan, Taiwan. . . . . . . . . . . . . . . . . . 920 - 925 MHz FHSS
Russia. . . . . . . . . . . . . . . . . . . . . . . . . . 868.7 - 869.2 MHz FHSS

Содержание WeatherLink Live 6100

Страница 1: ...Product number 6100 USER MANUAL WeatherLink Live Davis Instruments 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 www davisinstruments com R TM ...

Страница 2: ...esired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l appareil doit accepter tout brouillage radioelectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Innovation...

Страница 3: ...Link Live to your internet router You can also use WeatherLink Live with Amazon Alexa and Google Home Enable the WeatherLink Alexa skill or Google action then just say Alexa Okay Google ask WeatherLink to get my current conditions Components WeatherLink Live Requirements Tools Wi Fi or router Ethernet internet connection 2 4 GHz Wi Fi password Smartphone 4 AA batteries not included Install the Wea...

Страница 4: ...teries alone It is highly recommended that you install batteries to prevent loss of data if AC power is lost If AC power is lost and you have installed batteries the WeatherLink Live will stop trying to communicate with your network but it will continue to receive and store sensor data When AC power is resumed it will reconnect and send the records it stored during the outage to the WeatherLink Cl...

Страница 5: ...lt rate of 15 minutes is appropriate for most users To learn how to change this rate see page 5 How can I change my archive rate 2 In the next screen a map opens with the location of your station You can change this by moving the pin Tap Next 3 Agree to the conditions on the next screen 4 In the next screens choose Wi Fi or Ethernet For Wi Fi select your Wi Fi network and enter the network passwor...

Страница 6: ... see image on page 1 to wake it up If the LED still does not come on make sure your WeatherLink Live is connected to AC power If so try removing power AC and batteries and re powering the WeatherLink Live My WeatherLink Live will not connect to the internet If using a Wi Fi connection Check to make sure you entered the correct Wi Fi password The app requires a Wi Fi with a password If using an Eth...

Страница 7: ...ion click Device Tier at the top of the page and apply the device upgrade to your WeatherLink Live 4 Click the Tools icon then choose Device Configuration 5 In the top box on the next screen click Edit Settings Choose 1 or 5 minutes in the Archive Rate menu Click Save How can I change what units I want to use In the WeatherLink app tap the Account icon at the top of the home screen Tap Units to ch...

Страница 8: ... mA Wi Fi Frequency Range Power 2412 2472 MHz 802 11b g n less than 72mW BLE Frequency Range Power 2402 2480 MHz less than 1mW Sensor Data internal sensors Barometric Pressure Resolution and Units 0 01 Hg 0 1 mm 0 1 hPa 0 1mb user selectable Range 16 00 to 32 50 Hg 410 to 820 mm Hg 540 to 1100 hPa or mb Elevation Range 1500 to 15 300 460 m to 4670 m Update Interval 1 minute Inside Relative Humidit...

Отзывы: