DIAGNOSTICS  

SET 

The diagnostic screen

 is used by our tech support staff to help diag-

nose problems. If you experiencing difficulties call us at 

(510) 732-7814

Monday through Friday, 7:00 a.m. to 5:30 p.m., Pacific Time. 

 

To check reception and/or change antenna gain:  

1. To enter the diagnostic screen, press and hold

  TEMP  

and then press

 

 HUM 

. You will see GAIN ON or GAIN OFF in the ticker tape.

 

2. Look for the number with the % sign in the middle of the top row. A 

number >= 70% is good or excellent. If the number you see is < 70%, 
try changing the gain or relocating the console. Sometimes moving the 
console just a few feet can make a big difference. 

3. Press 

  2

ND

  

 CHILL 

 to toggle between diagnostic screen displays. 

4. To change antenna gain, press

  HI/LOW 

. Set GAIN OFF if there are 

multiple transmitters (such as cordless phones or baby monitors) in the 
area. Set GAIN ON if the transmitter and console are far apart or there 
are physical barriers (trees, walls, or large appliances) between them.  

5. To exit the diagnostic screen, press 

 DONE 

 

To set an alarm:  

1. Press

 

 

ALARM

  to enter the alarm screen. The      icon will appear on 

the screen. In each field, you will either see the alarm setting or, if no 
alarm has been set, a series of dashes. 

2. Press 

2

ND

 & 

 TIME 

 or a weather variable key, or use 

( + ),

 

( – )

( < )

, or

( > )

to move between weather variables. Except for the time alarm, the 

graph icon displays next to the variable you have selected.  

3. Press 

 HI/LOW 

 to switch between high and low alarms. (Note: Not 

all alarms are available for all weather variables. See 

Vantage Pro2 

Console Manual

 for details.) 

4. Press

  2

ND

  

 SET 

 to enter or change an alarm setting. Use 

( + ) 

or  

( – )

 to change the digit within a field. Use 

( < )

 or 

( > )

 to move to the 

next field.  

5. Press 

 DONE 

 to accept the alarm setting. Repeat steps 2–4 to set 

another alarm, or press 

 DONE 

 again to exit the alarm screen.  

The 

 SET 

 

key is also used

 to enter selected daily, monthly, and 

yearly totals and to calibrate selected readings. (See 

Console Manual

.)

 

 25 

 

 

Содержание Vantage Pro2 Updater

Страница 1: ...ve Hayward CA 94545 U S A Phone 510 732 9229 Fax 510 732 9188 www davisnet com E mail sales davisnet com support davisnet com Part Number 07395 235 Rev A 9 17 04 2004 by Davis Instruments Corp All rig...

Страница 2: ...nt Heat Index THWS Index Temp 1 4 from Leaf Wetness Station Ticker Tape If you have a UV sensor press 2 ND and UV to toggle be tween UV Index UV Dose meds Inside Temperature Temp 2 8 from Temp or Temp...

Страница 3: ...to the current weather screen To correct the time of sunrise and sunset Enter latitude longitude and time zone in setup screen See SETUP Press the appropriate key s to view these messages Forecast wit...

Страница 4: ...west to east 4 TIME ZONE Press or to view time zones Press 2ND to enter GMT offset instead of time zone Press or to change GMT offset 5 DAYLIGHT SAVINGS AUTO MANUAL Press or To change the setting 6 DA...

Страница 5: ...OF RAIN will appear in the ticker tape when you are displaying rain rate Press 2 ND to select the second key function printed in white type above each key The icon will appear in upper right corner o...

Страница 6: ...in 0 0 mm 0 0 hPa 0 0 mb Press 2 ND UNITS to change unit of measure To correct for elevation change 1 Press and hold DONE and then press to enter the setup screen 2 Press DONE nine times or until you...

Страница 7: ...ph will flash To exit the high low screen Press DONE To clear highs lows See CLEAR To clear a daily monthly or yearly amount 1 Select the variable you wish to clear 2 Press 2 ND then CLEAR holding CLE...

Страница 8: ...ill also change as you move back and forward on the graph To graph highs lows Press or to change the graph to the highs and lows for the last 24 days months or years Press HI LOW to switch between hig...

Страница 9: ...ers Update interval ET is updated once an hour on the hour Update Interval The forecast is updated once an hour on the hour Forecast Icons The forecast icons predict the weather within the next twelve...

Страница 10: ...ss 2 ND HEAT to toggle between Heat Index F C THSW Temp Hum Wind Sun Index F C if you have solar radia tion sensor Press 2 ND UNITS to change unit of measure All temperature related readings inside an...

Страница 11: ...hers On the ticker tape WIND CHILL WARNING will appear on the ticker tape when you are displaying wind chill if the reading is 0 F 18 C and the 10 minute av erage wind speed is 10 mph 16 km h Press HU...

Страница 12: ...ALARM to enter the alarm screen Press and hold ALARM until dashes appear in all the fields Press DONE to exit the alarm screen To clear individual alarm settings See CLEAR Press RAIN DAY to toggle be...

Страница 13: ...er and console are far apart or there are physical barriers trees walls or large appliances between them 5 To exit the diagnostic screen press DONE To set an alarm 1 Press ALARM to enter the alarm scr...

Страница 14: ...to the RESTRANSMIT message in Setup Mode 3 Press or to set the retransmit capability ON or OFF 4 Press or to advance to the next free station ID 5 Press and hold DONE to return to the current weather...

Страница 15: ...2 ND Used to select the variable or function printed in white above each key Umbrella Appears when it is currently raining Press 2 ND UNITS to change the unit of measure for a selected variable All t...

Страница 16: ...time to return to the current weather screen See DONE For instructions about LEAF WETNESS see HUM SOIL MOISTURE see TEMP Press WIND to toggle between Wind Speed 0 mph 0 0 m s 0 km h 0 knots Wind Dire...

Отзывы: