23

2. Remove the rain collector cone if it is installed on the sensor suite mounting base.
3. Insert the 1/4" x 3" lag screws through the metal backing plate and the holes in the 

mounting base into the post. Make sure the sensor suite is level by checking the 
built-in bubble level.

4. Tighten the lag screws using an adjustable wrench or 7/16" wrench. 

Install the Anemometer

1. With a 3/16" (5 mm) drill bit, drill two holes approximately 2

1

/

8

" (54 mm) apart. 

Use a carpenter’s level to ensure the holes will be level.

2. Insert the 1/4" x 3" lag screws through the flat washers and the holes in the 

anemometer mounting base into the post. 

3. Tighten the lag screws using an adjustable wrench or 7/16" wrench.

Note: 

If your anemometer arm cannot be mounted aiming true north, you will need to 
calibrate the wind direction on your console to display accurate wind directions. See 
your 

Vantage Pro2 Console User Manual.

Installing the Sensor Suite and Anemometer on a Pole

When installing the sensor suite on a pole, the rain collector /radiation shield section 
of the sensor suite and the anemometer can be mounted together as a single unit, or 
the two sections can be mounted separately. 

Accessories for Pole Mounting

• Use the Mounting Tripod (#7716) for easy roof-mounting. 
• Use the Mounting Pole Kit (#7717) to raise the installation height of the sensor 

suite by up to 37.5" (0.95 m).

U-Bolts:

1/4" Hex Nut

1/4" Lock Washer

Backing Plate

Rain Collector

Mounting Base

Groove for

U-Bolt

1/4" Flat Washer

1/4" Lock Washer

1/4" Hex Nut

Anemometer

Mounting Base

Anemometer U-Bolt         Rain Collector U-Bolt

Built-in bubble level 

behind tipping spoon mechanism

Содержание Vantage Pro2 GroWeather 6820

Страница 1: ...or Suite with Solar Radiation Sensor USER MANUAL Davis Instruments 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 www davisnet com R Product numbers 6820 and 6820C Vantage Pro2 GroWeather...

Страница 2: ...crease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced r...

Страница 3: ...receivers within its range The sensor suite includes a rain collector temperature sensor humidity sensor anemometer and solar radiation sensor Temperature and humidity sensors are mounted in a passiv...

Страница 4: ...ser at any time during the installation clean the diffuser using a soft damp cloth Anemometer Vane Wind Cups Anemometer Cable 40 12 2 m Anemometer Base Anemometer Arm Control Head Console Cable 100 30...

Страница 5: ...ectric if possible Scissors or wire cutters 7 16 wrench or adjustable wrench Compass or local area map Ballpoint pen or paper clip or other small pointed object Drill and 3 16 5 mm drill bit if using...

Страница 6: ...anemometer Anemometer arm wind vane and cable already attached Anemometer base Wind cups Allen wrench 0 05 4 machine screw 4 tooth lock washer 4 hex nut Attach the Anemometer Arm to Base 1 Insert the...

Страница 7: ...sh the wind cups up onto the anemometer s stainless steel shaft sliding them up the shaft as far as possible 2 Use the Allen wrench provided to firmly tighten the set screw on the side of the wind cup...

Страница 8: ...Pull the tab away from the box while sliding the cover up 4 Look on the side of the shelter The box cover can be easily removed from the box when the alignment indicator on the cover is lined up with...

Страница 9: ...same pole as the rain collector 1 Remove the protective cap from the RJ jack on the anemometer cable 2 Pull the foam insert out of cable access port and set it aside 3 Insert the anemometer cable end...

Страница 10: ...sensor suite base Tip When new the cone fits tightly in the base and may require extra pressure to remove Steady the sensor suite base between your knees when removing the cone 2 Carefully cut and re...

Страница 11: ...he spoons The console or Vantage Connect must be configured to 0 2 mm as well See your console or Vantage Connect user guide for more information To install the metric adapter 1 Find the metric adapte...

Страница 12: ...ector tab down 3 On the sensor interface firmly insert either end of the 4 conductor cable into the modular receptacle labeled COMM 4 If you haven t powered up the console yet refer to the installatio...

Страница 13: ...ss 2ND then press RAIN DAY for solar radiation readings The solar reading displays in the bottom right corner of the console display Solar readings should be zero or close to zero if the sensor suite...

Страница 14: ...o the ISS jack on the console Make sure that the cable is firmly plugged into the jack labeled COMM on the sensor interface Verify that all sensor cables are firmly plugged in A green LED indicator li...

Страница 15: ...ensor suite should begin communicating automatically when power is applied Note If there is another Davis weather station within range of your console or Vantage Connect you should change the Transmit...

Страница 16: ...weather data displayed on the console confirms successful communication Once the sensor suite has been powered and the console has successfully received accurate readings from all the sensors prepare...

Страница 17: ...g the wireless transmission still exists please contact Technical Support See Contacting Technical Support on page 32 8 When you are finished testing wireless transmission set DIP switch 4 to OFF to t...

Страница 18: ...f station that can be used with a single Vantage Pro2 console The console can receive signals from a total of up to eight transmitters stations Replaces the sensor suite anemometer Two are allowable o...

Страница 19: ...ping or flat regularly mowed grassy or naturally landscaped area that drains well when it rains For areas with average maximum yearly snow depths over 3 0 9 m mount the sensor suite 2 0 6 m above this...

Страница 20: ...ecommend using the optional mounting tripod 7716 For other installations use the Mounting Pole Kit 7717 Note For more detailed siting suggestions see Application Note 30 Reporting Quality Observations...

Страница 21: ...r air conditioners Transmission between wireless units may be obscured by something unidentifiable or by some obstacle that can t be worked around For best results orient the sensor suite antenna and...

Страница 22: ...more information on the diagnostic screens It s a good idea to test the console s reception anywhere that you might want to use or mount it now or in the future Take your time If you aren t picking up...

Страница 23: ...he Northern Hemisphere the solar panel should face south for maximum sun exposure and the anemometer arm should point north for proper wind direction calibration In the Southern Hemisphere the solar p...

Страница 24: ...pole together or separately Note All installations require that the rain collector cone be removed for assembly Use the built in bubble level to ensure the main part of the sensor suite is level Insta...

Страница 25: ...mometer arm cannot be mounted aiming true north you will need to calibrate the wind direction on your console to display accurate wind directions See your Vantage Pro2 Console User Manual Installing t...

Страница 26: ...the unit to the correct direction and then tighten the hex nuts The desired height can also be achieved by sliding the sensor suite vertically before tightening Option 1 Installing Sensor Suite and An...

Страница 27: ...he backing plate with a washer a lock washer and a hex nut on each of the bolt ends Do not tighten the nuts yet 3 For the wireless sensor suite swivel the sensor suite base so the solar panel is facin...

Страница 28: ...e cone The sockets are tapered push firmly or tap lightly with a hammer for a more secure fit If you choose not to install the spikes we recommend that you keep the packet of spikes in case birds beco...

Страница 29: ...ions Extending Wireless Transmission Range Optional repeater stations can be used to extend the wireless transmission range Wireless Repeater AC Powered 7626 or Solar Powered 7627 Long Range Wireless...

Страница 30: ...sor away from the sensor suite you can extend the length of the sensor cables up to 125 38 m with Davis Instruments extension cables 7876 Optional Wireless Stations You may use our optional wireless s...

Страница 31: ...diode and an amplifier Try not to touch the small white diffuser on top of the sensor Oil from skin reduces its sensitivity If you are concerned that you have touched the diffuser at any time clean th...

Страница 32: ...time to inspect and clean any debris or dust from the temperature humidity sensor assembly which is located on the underside of the top plate in the radiation shield To thoroughly clean the radiation...

Страница 33: ...the sensor to the sensor suite See Check Sensor Interface Connections and Connect the Anemometer Cable on page 6 Loose connections account for a large portion of potential problems Connections should...

Страница 34: ...f none of these steps get the wind direction working contact Technical Support and ask for a wind test cable The wind cups don t spin or don t spin as fast as they should The anemometer may be located...

Страница 35: ...HSS EU UK and OV models 868 0 868 6 MHz FHSS power output less than 10 mW Transmitter ID codes 8 user selectable License Low power less than 8 mW no license required Primary power Solar power Davis so...

Страница 36: ...s Quality Management System is ISO 9001 certified 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 Fax 510 732 9188 E mail info davisnet com www davisnet com Sensor Interface SENSOR SENSOR...

Отзывы: