
SONIC-ANEMO-DZP
© LCJ Capteurs 2016 – All rights reserved.
Page 4
We recommend installing the sensor at a height of 3 metres in a clear environment and a minimum of 10
metres from nearby objects.
b) Height of mounting
When the sensor is installed on the
top of a building roof, the
installation height must be equal to
the building's length or, if possible,
5 times the building's height.
Install the sensor in the middle of
the roof when possible. It is not
recommended to install a sensor on
a slanted roof. These roofs
generate upwards turbulences that
will affect the sensor.
c) Alignment of the sensor
The sensor must be aligned to North. An alignment tool is supplied for this
purpose. Clip the tool on the tube and slide it so that it snaps into the dedicated
slots. Do not tamper with the slots. The tool must gently find its place.
Slightly loosen the 4 screws that hold the tube. Align the tool - and the sensor - to
North. Tighten the screws.
Note: Magnetic deviation must be considered to reference the
measurements to True North.
d)
Mounting methods
The SONIC-ANEMO-DZP comes with a mounting bracket allowing two mounting methods: