USER

MANUAL

Product number: 6410

for Vantage Pro2™ and
EnviroMonitor®

Davis Instruments, 3465 Diablo Avenue, Hayward, CA 94545-2778 U.S.A. • 510-732-9229  •  www.davisinstruments.com

R

Содержание 6410

Страница 1: ...Anemometer USER MANUAL Product number 6410 for Vantage Pro2 and EnviroMonitor Davis Instruments 3465 Diablo Avenue Hayward CA 94545 2778 U S A 510 732 9229 www davisinstruments com R...

Страница 2: ......

Страница 3: ...can be used with EnviroMonitor or any Vantage Pro2 compatible system Installed in a Sensor Transmitter it can be used to include additonal wind stations in your existing system when reporting to a We...

Страница 4: ...r Attach the Wind Vane The wind direction has been calibrated in the factory so that the wind direction will be correct when the arm is installed pointing north and the vane is installed correctly 1 S...

Страница 5: ...nd cups should drop slightly when you let go 5 Ensure that the set screw is screwed in fully and very tight Failure to do so will cause the anemometer to function improperly 6 Spin the wind cups 7 If...

Страница 6: ...arm 4 Slide the tooth lock washer and hex nut onto the machine screw Tighten the hex nut while holding the screw with a Phillips head screwdriver to prevent it from turning 5 Press the sensor cable fi...

Страница 7: ...s See your console user manual For best results place the anemometer at least 7 2 1 m above surrounding obstructions such as trees or buildings that obstruct wind flow If mounting on a roof mount the...

Страница 8: ...to the wood Installing the Anemometer on a Pole or Pipe Use the Mounting Tripod 7716 for easy roof mounting Use the Mounting Pole Kit 7717 to raise the installation height by up to 37 5 0 95 m With th...

Страница 9: ...ting north 3 Using an adjustable wrench or 7 16 wrench tighten the hex nuts until the anemometer is firmly fastened on the pole Securing the Cable To prevent fraying or cutting the anemometer cable wh...

Страница 10: ...n a site Attaching the anemometer cable to the mounting pole using the supplied cable tie is the recommended option Keep the anemometer cable coiled if possible during the anemometer assembly so that...

Страница 11: ...move any extensions and try it with the anemometer cable only If none of these steps get the wind direction working contact Technical Support and ask for a wind test cable The wind cups don t spin or...

Страница 12: ...acting Davis Technical Support For questions about installing or operating your Anemometer please contact Davis Technical Support We ll be glad to help Note Please do not return your unit for repair w...