Davies Craig 0500 Скачать руководство пользователя страница 6

 

19/12/2018 

 

DIGITAL GAUGE THERMATIC

 FAN/EWP

 SWITCH

 

 

6 | 

P a g e

 

DIGITAL GAUGE THERMATIC

®

 FAN/EWP

®

 SWITCH OPERATION 

SETTING TARGET TEMPERATURE 

factory set to 85°C (185°F)

 

 

Push the 

‘Fan Button’

 once to indicate the present temperature setting. 

 

‘Fan 1 Button’ 

adjusts Fan 1’s set temperature. 

 

‘Fan 2 Button’ 

adjusts Fan 2’s set temperature.    

 

Push the 

‘Fan Button’

 again to increment set temperature by 1 unit. 

 

Push hold the 

‘Fan Button’ 

down to scroll through the temperature range. 

 

Start the engine and allow the temperature to reach normal operating temperature.  

 

Once  normal  operating temperature  is reached set 

‘Fan 1’ 

to  10°C  (18°F)  above 

temperature displayed.  

 

Once target temperature is reached release the button. The new target temperature 

will automatically be saved after 3 seconds unless the 

‘Fan Button’

 is pressed again.

 

 

 

If the other 

‘Fan Button’

 is pressed the target temperature change is cancelled. 

 

It is recommended that 

‘Fan 2’ 

is set to at least 15°C (27°F) above normal operating 

temperature.  

 

When only 

‘Fan 1’

  is being used 

‘Fan 2’ 

should be adjusted to match 

‘Fan 1’ 

target temperature. 

ADJUSTING A/C OVERRIDE CONTROL

 

 

Push the 

‘A/C Button’

 to select what fan is activated by the A/C override. 

 

Select from FAN 1, FAN 2, BOTH (shown as 1 – 2) 

ACTIVATING MANUAL OVERRIDE FUNCTION

 

 

Push the 

‘Fan 1 Button’ 

and 

‘A/C Button’

 for 2 second to turn 

OFF

 Fan 1. 

 

Push the 

‘Fan 1 Button’ 

and 

‘A/C Button’

 for 2 second to cancel override. 

 

Push the 

‘Fan 2 Button’ 

and 

‘A/C Button’

 for 2 second to turn 

OFF

 Fan 2. 

 

Push the 

‘Fan 2 Button’ 

and 

‘A/C Button’

 for 2 second to cancel override.   

ALARM FUNCTION  

 

Over set temperature.  

 

Fan activated. 

 

Tempe 10°C (18°F) over highest set temperature. 

 

Temperature display flashing.  

 

Audible alarm goes off once.  

 

Manual override cancelled. 

 

Tempe 20°C (36°F) over highest set temperature. 

 

 

Temperature display Flashing. 

 

Audible alarm goes continuously. 

 

Press 

‘Fan 1 Button’ 

or 

‘Fan 2 Button’

 to turn off alarm for 5 minutes. 

 

Содержание 0500

Страница 1: ...tal Gauge Wiring Loom 1 x Rubber Gauge Retainer 1 x U Bracket Gauge Mount 1 x Double Sided Tape Disc 1 x Sensor Probe Mounting Kit 2 x 15 Amp Fuses 2 x 30 Amp Fuses 2 x 12v 40 Amp Relays 2 x Fan Wiring Harnesses 2 x 5mm Ring Terminals 2 x Yellow 6mm Ring Terminals 2 x Yellow Connectors 6 x Scotch Locks 3 x Self Tapping Screws FUNCTIONS KEY FEATURES Temperature setting range 5 C 110 C 41 F 230 F Se...

Страница 2: ...the Gauge Carefully push the Gauge Display into the Gauge Stand ensuring the rubber retainer ring is installed on the Gauge Display Be mindful of the orientation of Gauge Display as it can be hard to rotate once fully installed into the Gauge Stand DIGITAL GAUGE THERMATIC FAN EWP SWITCH WIRING Ensure all wiring is protected from rubbing on bare metal or other sharp edges Locate a hole in the firew...

Страница 3: ...19 12 2018 DIGITAL GAUGE THERMATIC FAN EWP SWITCH 3 P a g e DIGITAL GAUGE THERMATIC FAN EWP WIRING DIAGRAM ...

Страница 4: ... fins Push the locking button and sensor onto the quick mount rod to sit flush with the face of the radiator Cut off excess quick mount rod Installation directly into coolant requires part 0409 or 0465 NOT SUPPLIED THREADED PORT INSTALLATION REQUIRES 0465 Ideal for installing the Thermal Sensor into the thermostat housing engine block or directly into the radiator Replace the Temperature Sensor Pr...

Страница 5: ...FAN INSTALLATION Install your fan s as per the instructions included with your fan s To wire your fan s relay please follow wiring instructions provided below For correct operation please ensure the fan s blade is rotating in the correct direction THERMATIC FAN WIRING CONNECTIONS THERMATIC FAN WIRING DIAGRAM FAN Relay Pin Wire colour Connection location 85 BLACK BLUE OR ORANGE Fan wire 86 GREEN Ig...

Страница 6: ...target temperature change is cancelled It is recommended that Fan 2 is set to at least 15 C 27 F above normal operating temperature When only Fan 1 is being used Fan 2 should be adjusted to match Fan 1 target temperature ADJUSTING A C OVERRIDE CONTROL Push the A C Button to select what fan is activated by the A C override Select from FAN 1 FAN 2 BOTH shown as 1 2 ACTIVATING MANUAL OVERRIDE FUNCTIO...

Страница 7: ...st applications but there are circumstances surrounding some engine designs environments and the nature of the system involved which may require other installation arrangements not outlined here Frequently Asked Questions FAQ are listed on our website www daviescraig com au Emails can be directed to info daviescraig com au or Telephone 61 0 3 9369 1234 during business hours WARRANTY Davies Craig P...

Страница 8: ......

Отзывы: