![Davies Craig 0500 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/davies-craig/0500/0500_installation-instructions-manual_514580006.webp)
19/12/2018
DIGITAL GAUGE THERMATIC
FAN/EWP
SWITCH
6 |
P a g e
DIGITAL GAUGE THERMATIC
®
FAN/EWP
®
SWITCH OPERATION
SETTING TARGET TEMPERATURE
factory set to 85°C (185°F)
Push the
‘Fan Button’
once to indicate the present temperature setting.
‘Fan 1 Button’
adjusts Fan 1’s set temperature.
‘Fan 2 Button’
adjusts Fan 2’s set temperature.
Push the
‘Fan Button’
again to increment set temperature by 1 unit.
Push hold the
‘Fan Button’
down to scroll through the temperature range.
Start the engine and allow the temperature to reach normal operating temperature.
Once normal operating temperature is reached set
‘Fan 1’
to 10°C (18°F) above
temperature displayed.
Once target temperature is reached release the button. The new target temperature
will automatically be saved after 3 seconds unless the
‘Fan Button’
is pressed again.
If the other
‘Fan Button’
is pressed the target temperature change is cancelled.
It is recommended that
‘Fan 2’
is set to at least 15°C (27°F) above normal operating
temperature.
When only
‘Fan 1’
is being used
‘Fan 2’
should be adjusted to match
‘Fan 1’
target temperature.
ADJUSTING A/C OVERRIDE CONTROL
Push the
‘A/C Button’
to select what fan is activated by the A/C override.
Select from FAN 1, FAN 2, BOTH (shown as 1 – 2)
ACTIVATING MANUAL OVERRIDE FUNCTION
Push the
‘Fan 1 Button’
and
‘A/C Button’
for 2 second to turn
OFF
Fan 1.
Push the
‘Fan 1 Button’
and
‘A/C Button’
for 2 second to cancel override.
Push the
‘Fan 2 Button’
and
‘A/C Button’
for 2 second to turn
OFF
Fan 2.
Push the
‘Fan 2 Button’
and
‘A/C Button’
for 2 second to cancel override.
ALARM FUNCTION
Over set temperature.
Fan activated.
Tempe 10°C (18°F) over highest set temperature.
Temperature display flashing.
Audible alarm goes off once.
Manual override cancelled.
Tempe 20°C (36°F) over highest set temperature.
Temperature display Flashing.
Audible alarm goes continuously.
Press
‘Fan 1 Button’
or
‘Fan 2 Button’
to turn off alarm for 5 minutes.
Содержание 0500