Davies Craig 0500 Скачать руководство пользователя страница 2

 

19/12/2018 

 

DIGITAL GAUGE THERMATIC

 FAN/EWP

 SWITCH

 

 

2 | 

P a g e

 

DIGITAL GAUGE THERMATIC

®

 FAN/EWP

®

 SWITCH MOUNTING 

The  Digital  Gauge  Thermatic

®

  Fan/ EWP

®

  Switch  is compatible with many 52mm 

Gauge stands and mounts. 

 

 

The Digital Gauge Thermatic

®

 Fan/ EWP

®

 Switch MUST be mounted inside the 

passenger compartment to minimise its ambient temperature and exposure to 

water. 

 

For a neat installation the Gauge Display can be mounted to the underside of 

the dash to avoid drilling holes in the dash or having exposed wiring.  

 

Locate or drill a minimum 13mm hole in the dash and pass the wiring loom 

through leaving the 

‘loom connector’

 free to plug into the Gauge. 

 

Thermal Sensor wire MUST NOT be cut in ANY circumstances.

 

 

Ensure the mounting location allows easy access to the 3 set buttons.  

 

If using an alternative mounting method follow appropriate installation 

procedure.  

 

Mount the Gauge Stand in position. This can be done using the two screw holes in 

the base of the stand or with the double-sided tape disc. 

 

Pass the 

‘loom connector’

 through the rectangular hole in the back of the Gauge 

Stand and plug into the socket of the Gauge. 

 

Carefully push the Gauge Display into the Gauge Stand ensuring the rubber 

retainer ring is installed on the Gauge Display. 

 

Be mindful of the orientation of Gauge Display as it can be hard to rotate once 

fully installed into the Gauge Stand.  

DIGITAL GAUGE THERMATIC

®

 FAN/EWP

®

 SWITCH WIRING 

Ensure all wiring is protected from rubbing on bare metal or other sharp edges.

 

 

 

Locate a hole in the firewall (approx.15 mm in diameter) and pass the required 

wiring (below) through the firewall from the passenger cabin to the engine bay. 

 

BLUE

 

“FAN 1” 

wire. 

 

ORANGE

 

“FAN 2”

 wire. 

 

Temperature probe wiring. 

 

GREEN

 

“AIR CONDITONER”

 wire (OPTIONAL).

 

 

If using the

 “AIR CONDITONER”

 wire as a manual override simply 

connect it to a positive source though toggle switch. 

 

Locate a Positive ignition or accessories source within the passenger compartment 

and connect the 

RED

 

“IGNITION”

 wire. 

 

Connect the 

BLACK

 

“EARTH”

 wire to the chassis or negative Earth supply. 

 

If using the Dimmer function locate a positive source that is controlled by the 

headlight switch and connect the 

 

“DIMMER”

 wire. 

YELLOW

 

If an appropriate source cannot be located you will need to run the 

 

YELLOW

“DIMMER”

 wire through the firewall and connect it to the positive feed of one 

of the headlights.

  

*For positive earth systems, wire ‘Earth’ to battery negative not the chassis 

Содержание 0500

Страница 1: ...tal Gauge Wiring Loom 1 x Rubber Gauge Retainer 1 x U Bracket Gauge Mount 1 x Double Sided Tape Disc 1 x Sensor Probe Mounting Kit 2 x 15 Amp Fuses 2 x 30 Amp Fuses 2 x 12v 40 Amp Relays 2 x Fan Wiring Harnesses 2 x 5mm Ring Terminals 2 x Yellow 6mm Ring Terminals 2 x Yellow Connectors 6 x Scotch Locks 3 x Self Tapping Screws FUNCTIONS KEY FEATURES Temperature setting range 5 C 110 C 41 F 230 F Se...

Страница 2: ...the Gauge Carefully push the Gauge Display into the Gauge Stand ensuring the rubber retainer ring is installed on the Gauge Display Be mindful of the orientation of Gauge Display as it can be hard to rotate once fully installed into the Gauge Stand DIGITAL GAUGE THERMATIC FAN EWP SWITCH WIRING Ensure all wiring is protected from rubbing on bare metal or other sharp edges Locate a hole in the firew...

Страница 3: ...19 12 2018 DIGITAL GAUGE THERMATIC FAN EWP SWITCH 3 P a g e DIGITAL GAUGE THERMATIC FAN EWP WIRING DIAGRAM ...

Страница 4: ... fins Push the locking button and sensor onto the quick mount rod to sit flush with the face of the radiator Cut off excess quick mount rod Installation directly into coolant requires part 0409 or 0465 NOT SUPPLIED THREADED PORT INSTALLATION REQUIRES 0465 Ideal for installing the Thermal Sensor into the thermostat housing engine block or directly into the radiator Replace the Temperature Sensor Pr...

Страница 5: ...FAN INSTALLATION Install your fan s as per the instructions included with your fan s To wire your fan s relay please follow wiring instructions provided below For correct operation please ensure the fan s blade is rotating in the correct direction THERMATIC FAN WIRING CONNECTIONS THERMATIC FAN WIRING DIAGRAM FAN Relay Pin Wire colour Connection location 85 BLACK BLUE OR ORANGE Fan wire 86 GREEN Ig...

Страница 6: ...target temperature change is cancelled It is recommended that Fan 2 is set to at least 15 C 27 F above normal operating temperature When only Fan 1 is being used Fan 2 should be adjusted to match Fan 1 target temperature ADJUSTING A C OVERRIDE CONTROL Push the A C Button to select what fan is activated by the A C override Select from FAN 1 FAN 2 BOTH shown as 1 2 ACTIVATING MANUAL OVERRIDE FUNCTIO...

Страница 7: ...st applications but there are circumstances surrounding some engine designs environments and the nature of the system involved which may require other installation arrangements not outlined here Frequently Asked Questions FAQ are listed on our website www daviescraig com au Emails can be directed to info daviescraig com au or Telephone 61 0 3 9369 1234 during business hours WARRANTY Davies Craig P...

Страница 8: ......

Отзывы: