Davies Craig 0500 Скачать руководство пользователя страница 1

 

19/12/2018 

 

DIGITAL GAUGE THERMATIC

 FAN/EWP

 SWITCH

 

 

1 | 

P a g e

 

77 Taras Avenue 

P.O. Box 363 

Altona North 

Vic 3025 Australia 

Phone:  +61(0)3 9369 1234 

Fax:       +61(0)3 9369 3456 

[email protected] 

www.daviescraig.com.au 

 

DIGITAL GAUGE THERMATIC

®

 FAN/EWP

®

 SWITCH

 

INSTALLATION INSTRUCTIONS  

 

Congratulations on your purchase of the Davies, Craig Digital Gauge Thermatic

®

 

Fan/ EWP

®

 Switch. The Digital Gauge Thermatic

®

 Switch allows you to keep an eye 

on your cooling system’s temperature whilst it automatically controls single or twin 

Thermatic

®

 fans, or a combination of a Thermatic

®

 fan and Electric Water Pump 

(EWP

®

) or Electric Booster Pump (EBP

®

) at independent target temperatures for 

those times when extra cooling is required.  

 

PLEASE READ ALL THESE INSTRUCTIONS THOROUGHLY BEFORE YOU START WORK. 

DON’T RUSH - ENSURE YOU HAVE FULL UNDERSTANDING OF THE WORK AHEAD BEFORE 

YOU COMMENCE. ENSURE YOU HAVE ALL TOOLS AND COMPONENTS REQUIRED. 

COMPONENTS 

 

1 x Digital Gauge Display 

 

1 x Digital Gauge Stand 

 

1 x Digital Gauge Wiring Loom 

 

1 x Rubber Gauge Retainer 

 

1 x U-Bracket Gauge Mount 

 

1 x Double Sided Tape Disc 

 

1 x Sensor Probe Mounting Kit

 

 

2 x 15 Amp Fuses 

 

2 x 30 Amp Fuses 

 

2 x 12v 40 Amp Relays 

 

2 x Fan Wiring Harnesses 

 

2 x 5mm Ring Terminals   

 

2 x Yellow 6mm Ring Terminals 

 

2 x Yellow Connectors 

 

6 x Scotch Locks 

 

3 x Self-Tapping Screws   

 

FUNCTIONS 
KEY FEATURES: 

 

Temperature setting range.  

 

5°C 

 110°C (41°F 

 230°F). 

 

Selectable °C & °F. 

 

12v and 24v compatible.  

 

Universal 52mm Gauge design. 

 

Individual fan set temperature.  

 

Over temperature alarm with snooze 

function. 

 

LED temperature readout.  

 

LED status indicators.  

 

Extra-long temperature sensor wire. 

 

Display dimmer (optional).  

 

A/C override (optional). 

 

Works as manual override. 

 

Independent control of fan. 

overridden. 

SPECIAL FEATURES: 

 

Manually turn off either fan’s ‘control 

by temperature’ functionality. 

 

Disables (turns off) each fan.  

 

Interchangeable sensor. 

 

Replicable sensor probe. 

 

Can detect coolant temperature.  

 

Use #0409 for top radiator hose.  

 

Use #0465 for ¼” NPT port.  

 

Transmission fluid detection. 

 

Requires the use of #0465 and a 

sensor adaptor. 

 

Adaptor can be made using: 

 

1 x female tee ¼” NPT   

 

2 x barb fitting to ¼” NPT 

 

Barb to fit transmission hose 

(above parts sourced externally)

 

Содержание 0500

Страница 1: ...tal Gauge Wiring Loom 1 x Rubber Gauge Retainer 1 x U Bracket Gauge Mount 1 x Double Sided Tape Disc 1 x Sensor Probe Mounting Kit 2 x 15 Amp Fuses 2 x 30 Amp Fuses 2 x 12v 40 Amp Relays 2 x Fan Wiring Harnesses 2 x 5mm Ring Terminals 2 x Yellow 6mm Ring Terminals 2 x Yellow Connectors 6 x Scotch Locks 3 x Self Tapping Screws FUNCTIONS KEY FEATURES Temperature setting range 5 C 110 C 41 F 230 F Se...

Страница 2: ...the Gauge Carefully push the Gauge Display into the Gauge Stand ensuring the rubber retainer ring is installed on the Gauge Display Be mindful of the orientation of Gauge Display as it can be hard to rotate once fully installed into the Gauge Stand DIGITAL GAUGE THERMATIC FAN EWP SWITCH WIRING Ensure all wiring is protected from rubbing on bare metal or other sharp edges Locate a hole in the firew...

Страница 3: ...19 12 2018 DIGITAL GAUGE THERMATIC FAN EWP SWITCH 3 P a g e DIGITAL GAUGE THERMATIC FAN EWP WIRING DIAGRAM ...

Страница 4: ... fins Push the locking button and sensor onto the quick mount rod to sit flush with the face of the radiator Cut off excess quick mount rod Installation directly into coolant requires part 0409 or 0465 NOT SUPPLIED THREADED PORT INSTALLATION REQUIRES 0465 Ideal for installing the Thermal Sensor into the thermostat housing engine block or directly into the radiator Replace the Temperature Sensor Pr...

Страница 5: ...FAN INSTALLATION Install your fan s as per the instructions included with your fan s To wire your fan s relay please follow wiring instructions provided below For correct operation please ensure the fan s blade is rotating in the correct direction THERMATIC FAN WIRING CONNECTIONS THERMATIC FAN WIRING DIAGRAM FAN Relay Pin Wire colour Connection location 85 BLACK BLUE OR ORANGE Fan wire 86 GREEN Ig...

Страница 6: ...target temperature change is cancelled It is recommended that Fan 2 is set to at least 15 C 27 F above normal operating temperature When only Fan 1 is being used Fan 2 should be adjusted to match Fan 1 target temperature ADJUSTING A C OVERRIDE CONTROL Push the A C Button to select what fan is activated by the A C override Select from FAN 1 FAN 2 BOTH shown as 1 2 ACTIVATING MANUAL OVERRIDE FUNCTIO...

Страница 7: ...st applications but there are circumstances surrounding some engine designs environments and the nature of the system involved which may require other installation arrangements not outlined here Frequently Asked Questions FAQ are listed on our website www daviescraig com au Emails can be directed to info daviescraig com au or Telephone 61 0 3 9369 1234 during business hours WARRANTY Davies Craig P...

Страница 8: ......

Отзывы: