GENERAL SAFETY RULES 

!

WARNING

  Read all instructions. Failure to follow all instructions listed 

below may result in hazardous radiation exposure, electric 

shock, fire and/or serious injury.  
All labels on your laser are for your safety and must not be removed. Removing 

labels increases the risk of exposure to laser radiation. Do not throw this 

manual away.

If glass light house breaks when dropped, contact customer service 

immediately. 

Broken glass can cause laceration hazard and unit to 

lose its IP rating. 

DO NOT direct the laser beam at persons or animals and do not 

stare into the laser beam yourself. This tool produces laser class 

2 laser radiation and complies with 21 CFR 1040.10 and 1040.11 

except for deviations pursuant to Laser Notice No. 50, dated 

June 24, 2007. This can lead to persons being blinded.

DO NOT remove or deface any warning or caution labels.  

Removing labels increases the risk of exposure to laser radiation.

Use of controls or adjustments or performance of procedures other than those 

specified in this manual, may result in hazardous radiation exposure.
ALWAYS make sure that any bystanders in the vicinity of use are made aware 

of the dangers of looking directly into the laser tool.
DO NOT place the laser tool in a position that may cause anyone to stare into 

the laser beam intentionally or unintentionally. 

Serious eye injury could result.

Laser radiation. Do not stare into the beam or view directly with optical instruments. Class 2 
lasers product. Complies with  21 CFR 1040.10 & 1040.11 except for deviations persuant to 
Laser Notice 50, June 6, 2007
Radiación laser. No mire hacia el rayo. No mirar con instrumentos ópticos. Producto láser  de 
Clase 2. Cumple con las normas 21 CFR 1040.10 y 1040.11, excepto por las desviaciones 
conforme al Aviso para láseres 50, 6 de junio de 2007

Rayonnement laser. Ne pas regarder le rayon. Ne pas regarder avec instruments . 

Produit laser de Classe 2. Conforme à 21 CFR 1040.10 et 1040.11, sauf pour les 

écarts suivant l’Avis laser 50, 24/6/2007

IEC 60825-1:2007-03

≤ 3.43 mW @ 630 - 670 nm

Made in China
4 X C 1.5 V / Li-ion

Dave White’s SitePro, LLC | Otterbein, Indiana | www.dwsitepro.com

Содержание LR 410H

Страница 1: ...E D LR 430HDV www davidwhite us com LR 410H LR 430HDV Rotary Laser Owner s Guide FOR CUSTOMER SERVICE PARTS AND REPAIR CALL 765 581 4097 IMPORTANT IMPORTANT IMPORTANTE Read Before Using Lire avant usage Leer antes de usar ...

Страница 2: ...xtremely rugged field use Like all precision instruments however they should be treated with reasonable care to prolong life and accuracy All instruments are adjusted when they are shipped from the factory It is the customer s responsibility to check and to ensure instruments are adjusted prior to using David White is not responsible for errors caused by instruments that are out of adjustment Cont...

Страница 3: ... 3 M O D E A LA R M SP EE D LR 430HDV MODE ALARM SPEED 3 1 1 2 5 4 c g b d f a h e LR 430HDV ...

Страница 4: ... 4 M O D E A LA R M SP EE D LR 410H MODE ALARM SPEED 3 1 2 5 4 c g b d f a h e LR 410H ...

Страница 5: ... 5 10 11 9 7 8 5 6 4 Bottom of LR Series Shown LR 430HDV ...

Страница 6: ...performance of procedures other than those specified in this manual may result in hazardous radiation exposure ALWAYS make sure that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the laser tool DO NOT place the laser tool in a position that may cause anyone to stare into the laser beam intentionally or unintentionally Serious eye injury could result L...

Страница 7: ...vite accidents DO NOT operate the laser tool around children or allow children to operate the laser tool Serious eye injury could result DO NOT use instruments attachments and accessories outdoors when lightening conditions are present Electrical safety Batteries can explode or leak cause injury or fire To reduce this risk always follow all instructions and warnings on the battery label and packag...

Страница 8: ...laser beam directly into the eyes of others Serious eye injury could result Use caution when using instruments in the vicinity of electrical hazards Magnets Keep the tool and laser target away from cardiac pacemakers The magnets of the tool and laser target plate generate a field that can impair the function of cardiac pacemakers Keep the tool and laser target away from magnetic data medium and ma...

Страница 9: ...abusive conditions liquids can leave the batteries Avoid contact If you are in contact with the liquid clean with water If the liquid is in contact with your eyes seek medical attention The batteries must not be opened and must be protected from permanent sun Children must not play with the charger even not under supervision operation If damaged repair tool before use Many accidents are caused by ...

Страница 10: ... Label 7 Battery Lid 8 Latch of Battery Lid 9 Battery Charging Indicator 10 Battery Charging Port 11 Charging Port Plug TECHNICAL DATA LR 410H LR 430HDV Leveling Horizontal Horizontal w 90 Verticals Horizontal Accuracy 3 32 in at 100 ft 2 25mm at 30m 3 32 in at 100 ft 2 25mm at 30m Vertical Accuracy n a 1 8 in at 100 ft 3mm at 30m Angle Accuracy 20 20 Leveling Type Electronic Self Leveling 4º Elec...

Страница 11: ...teries or rechargeable Lithium ion Li ion battery pack are suitable for use to power your instrument WARNING Always replace all alkaline batteries at the same time Only use batteries from one brand and with the identical capacity Remove the batteries pack from the tool when not using it for extended periods When storing for extended periods the batteries can corrode and discharge themselves To ope...

Страница 12: ...urface mount it to a tripod or to the wall mount with alignment unit Due to the high leveling accuracy the instrument reacts sensitively to ground vibrations and position corrode and discharge themselves When using rechargeable Li ion batteries for the first time be sure to charge for several hours Charging Rechargeable Li ion Battery Pack sold separately If you are using rechargeable Li ion batte...

Страница 13: ...ore horizontal or level To switch off the instrument press and hold the power button 3a for three 3 seconds OPERATION MODES Variable Rotational Speed The rotational speed of the instrument can be adjusted while instrument is in rotational operation For optimal use with detector use 800 or 2000 rotations per minute RPM Press MODE ALARM SPEED 3e to adjust the rotational speed between 400 800 and 200...

Страница 14: ...ent to self level Alarm System The ALARM system alerts user when the laser instrument can not level When the ALARM indicator 3g flashes red light the laser is out of it self leveling range The ALARM indicator 3g lights up red and automatic self leveling is deactivated ACCURACY CHECK The ambient temperature has the greatest influence Especially temperature differences occurring from the ground upwa...

Страница 15: ...2 on wall is the actual deviation of the instrument for the measured axis The value of D deviation should be less than 7 32 in 5mm Checking the Vertical Alignment LR 430HDV Only A free measuring distance of 16 ft 5m on a firm surface is required Place the laser instrument on a flat level surface or mount onto a tripod approximately 16 ft 5m from a wall Hang a plumb bob from ceiling a minimum 6 ft ...

Страница 16: ...y 10 ft or 3m from the laser point P1 of the instrument and the opposite laser plane Mark this point A on the floor Measure the distance C between point A and B The value of C should be 15 ft 5m but may deviate within 1 32 in 0 8mm LD20 DETECTOR OPTIONAL Your instrument may include the LD20 Rotary Laser Detector If your David White instrument is packaged with another model or you would like learn ...

Страница 17: ...low indicator 4 Reception area for the laser beam 5 Button for adjustment of measuring accuracy 6 Spirit level 7 Speaker 8 Audio signal button 9 Locking screw for leveling rod 10 Magnetic mounts LD20 FEATURES Inserting Replacing the Battery 9V alkaline battery is recommended for the tool When the batteries are low the battery low indicator g will display Pull the latch of battery lid outward and o...

Страница 18: ...thorized after sales service center for Dave White s SitePro instruments In all correspondence and spare parts orders please always include the model number and serial number of the instruments All precision instruments should be cleaned lubricated checked and adjusted ONLY at a qualified instrument repair station or by the manufacturer at least once a year In case of repairs send in the instrumen...

Страница 19: ...ER RELATED ITEMS THESE ITEMS RECEIVE A 90 DAY LIMITED WARRANTY To make a claim under this Limited Warranty you must return the complete product transportation prepaid For details to make a claim under this Limited Warranty please visit www davidwhite com or call 1 855 354 9881 ANY IMPLIED WARRANTIES SHALL BE LIMITED IN DURATION TO ONE YEAR FROM DATE OF PURCHASE SOME STATES IN THE U S AND SOME CANA...

Страница 20: ... 20 ...

Страница 21: ... 21 ...

Страница 22: ...48LR3400 12 16 Dave White s SitePro Otterbein IN USA 1 765 581 4097 2017 Dave White s SitePro All rights reserved David White is a registered trademark and offered exclusively by SitePro www sitepro us com ...

Отзывы: