background image

 

 

 

 

5 of 10

 

 

 

 

 

19605P-23 (07-20) 

   

Figure 2: Positioning the Microphone 

Communication 

The user will hear his own voice (side-tone) only when the belt station is linked to a  gateway, 
assuming the microphone programming for intercom on the chosen selection is either hot-mic or 
VOX; if the selection for mic function for intercom was programmed for PTT, the user will hear 
side-tone when the PTT is depressed .  Side-tone provides feedback for the user to know he is 
connected.  In general, if you can hear your own voice, the other users can hear you as well. 

Range 

The unimpeded line-of-sight range of a belt station and a gateway should be at least 500 ft 
(150m).  If you are in an environment with metal or concrete walls, this range could be reduced.  
If the belt station enters into a "fringe" reception area, a brief sequence of three beeps will be 
heard in the headset.  This is to serve as a warning of a possible disconnection if conditions are 
not improved.  When possible, the user should attempt to regain line-of-sight contact with the 
gateway.  When the belt station travels out of range of the gateway, a voice prompt will indicate 
that the connection has been lost.  To reconnect, simply move back into range and connection 
with the gateway will automatically be reestablished, also noted by a voice prompt.  
 
PTT 

The PTT button allows the user to activate the headset's microphone momentarily while 
depressed. The actual microphone transmit function (e.g., radio transmit or intercom) will 
depend on the specific programming for the chosen selection on the belt station.  For more 
information see the Operation Digital Intercom manual (19549P-31). (see section on User 
Interface to review programming options). 
 
Selections 
 
The U9110-BSW(EU) has the capability of switching between four “selections”.  These selections 
are defined within the Digital Intercom System graphical user interface and can be configured to 
provide different communications paths between users and radios, as well as the behavior of 
auxiliary audio devices connected to the system.   
 

 

Содержание 40992G-20

Страница 1: ...19605P 23 07 20 2020 DAVID CLARK COMPANY INCORPORATED USER MANUAL Digital Wireless Belt Station U9110 BSW EU P N 40992G 20 ...

Страница 2: ......

Страница 3: ...is apparent immediately file a claim with the carrier and notify your David Clark product supplier ELECTRICAL HAZARD Disconnect electrical power when making any internal adjustments or repairs All repairs should be performed by a representative or authorized agent of the David Clark Company STATIC HAZARD Static electricity can damage components Therefore be sure to ground yourself before opening o...

Страница 4: ...4 EU 44002G 02 Digital Wireless Gateway becomes part of a wireless intercom system Up to four belt stations can be connected to one gateway Figure 1 Overview of Belt Station The U9110 BSW EU Digital Wireless Belt Station employs an adaptive SMART VOX system which does not require adjustment by the user The system automatically monitors background noise levels and detects voice ...

Страница 5: ...W EU will attempt to establish a connection with the gateway 6 Upon successfully establishing connection the LED will flash green a voice alert will be heard see Table 1 and user side tone will be enabled see Communication 7 Link and connection are now complete Each belt station is able to be linked to only one gateway at a time A gateway can have up to four belt stations linked connected at one t...

Страница 6: ... To power down the U9110 BSW EU press and hold the POWER button for approximately two seconds The LED will turn red and then turn off The belt station is now powered down Auto Shut off Additionally the belt station will automatically power down if it is disconnected from its gateway for more than 30 minutes Headset In order for the U9110 BSW EU to be used a David Clark H9100 series headset must be...

Страница 7: ...f conditions are not improved When possible the user should attempt to regain line of sight contact with the gateway When the belt station travels out of range of the gateway a voice prompt will indicate that the connection has been lost To reconnect simply move back into range and connection with the gateway will automatically be reestablished also noted by a voice prompt PTT The PTT button allow...

Страница 8: ...n gateway Typically purging is not necessary unless there are multiple gateways in the same vicinity and you wish to link a belt station to a different gateway A belt station can be linked to only one gateway at a time Purge Procedure 1 Power down belt station see Power up Power down 2 Press and hold PTT button Do not release 3 Power up the belt station see Power up Power down 4 Release POWER butt...

Страница 9: ...tery is installed Cannot link a belt station Review Registration procedure Ensure units are within 1 to 3 ft 0 3 to 0 9m of each other while linking No sidetone Not connected to a Gateway Low receive audio Adjust left right volume knobs on headset No audio intermittent audio Check headset connection to belt station Replacement Parts Battery P N 40688G 90 Protective skin black A99 01SKN P N 40796G ...

Страница 10: ... EU may be wiped down with a mild soap and water mixture Although it is designed as a water tight device do not unnecessarily submerse this product in water Avoid storage of this product in direct sunlight or high temperature environments Specifications Frequency Range 1880 MHz 1900 MHz EU Average RF Power Output 10 mW 250mW peak EU Range 500 ft 150m line of sight nominal Battery Life 24 hrs conti...

Страница 11: ...ly approved by David Clark Company Inc could void the users authority to operate the equipment Usage Restrictions Due to the UPCS frequencies used this product is licensed for operation only in the European Union Countries and those countries that have approved the DECT EU Standard ...

Страница 12: ...h the product transmitting at its highest certified power level in all used frequency bands The product is designed to meet the relevant guidelines for exposure to radio waves SAR data information for residents in countries that have adopted the SAR limit recommended by the International Commission of Non Ionizing Radiation Protection ICNIRP which is 0 08 W kg averaged over the whole body or 2 00 ...