background image

3

General

The purpose of these instructions is to ensure the correct installation and 

best performance of our pumps.
These are single cell centrifugal pumps with built-in filter elements, 

especially designed for prefiltering and recirculation of water in swimming 

pools.
They are designed to operate with clean water at a maximum temperature 

of 35°C. All materials used are of top quality; they are subjected to strict, 

controls and verified to extremely demanding standards.
Correct compliance with the installation and operation instructions, and with 

the electrical connection diagrams, will prevent motor overloads and the 

consequences of all types that could otherwise result, consequences for 

which we decline all responsibility.

Installation

The installation of our electric pumps is only permitted in 

swimming pools or ponds that meet DIN standards VDE 0100 

part 702/11.82. In case of doubt, inquire with an expert.

The pump should be installed as near as possible to water level, in 

horizontal position, in order to obtain a minimum suction path and reduce 

head losses.
It is not advisable to install the pump at more than 3 m geometrical height 

from water level.
Independently of the geometrical height and the power of the model 

chosen, self-priming times may be up to 10 min.
The pump must be fixed on a firm base, with screws of 6 or 8 mm diameter, 

through the prepared holes in the foot.
The pump should be protected from possible flooding and receive dry 

ventilation. The pump is to be installed in a manner consistent with the 

National Wiring Rules.

Содержание WHISPER Series

Страница 1: ...mply with all applicable codes may cause serious bodily injury and or property damage The installation of this product should be carried out by a person knowledgable in swimming pool plumbing requirem...

Страница 2: ...ps have been designed to circulate swimming pool and spa water in conditions set out in the Australian Standard for swimming pool water quality AS 3633 or equivalent They should not be used for any ot...

Страница 3: ...t consequences for which we decline all responsibility Installation The installation of our electric pumps is only permitted in swimming pools or ponds that meet DIN standards VDE 0100 part 702 11 82...

Страница 4: ...d be structured with a slight slant to prevent the formation of siphons Electrical connection IMPORTANT INFORMATION Your Davey pump is Double Insulated to Water Circuit If equipotential bonding struct...

Страница 5: ...lting the list of common faults and their possible solutions provided in this manual NEVER RUN THE PUMP DRY Starting Open all the gate valves and put the motor under voltage Wait a reasonable time to...

Страница 6: ...time comes to dispose of the pump it contains no toxic or contaminating materials The principal components are duly identified for selective breaking If the supply cord is damaged it must be replaced...

Страница 7: ...scant flow 3 Pump noisy 4 Pump does not start 5 Motor makes sound but does not start 1 2 3 4 5 Problem Solution X X Air entry through suction line Verify condition of connectors and gaskets of suction...

Страница 8: ...ll not be liable for any loss of profits or any consequential indirect or special loss damage or injury of any kind whatsoever arising directly or indirectly from Davey products This limitation does n...

Отзывы: