background image

9

7. SLEEP TIMER (Optional Timeclock) 

If the optional time clock has been fitted, sleep mode is used to 

disable automatic temperature maintenance and filtration in order 

to silence the spa pool during your hours of sleep.The sleep time 

setting is done using the digital time clock on the front of the control 

box (See below for setting instructions). If the spa is in use it will not 

enter sleep mode until 30 minutes after the last manual button push, 

even if the clock is calling for sleep mode. The spa can still be used 

manually within sleep mode times as normal. On wake up from sleep 

the system will run the blower for 15 seconds to purge the blower 

plumbing. This prevents any stagnant water from collecting in the 

pipes if the pool is not used for an extended period. 

7.1 To Set Current Time and Day  

1.  Press the 

RESET

 button before use. NOTE:This is optional. It will clear the current time 

and program settings. 

2.  Hold down the 

CLOCK 

button and press the 

DAY 

button until the correct day is selected. 

Release both buttons. 

3.  Hold down the 

CLOCK 

button and press the 

HOUR 

button until the correct hour is set. 

Release both buttons. 

4.   Hold down the 

CLOCK 

button and press the 

MIN 

button until the correct minute is set. 

Release both buttons. 

5.  After setting the weekday and time,the seconds will reset automatically and the clock will 

begin keeping time. 

7.2 To Set Programs 

1.   Press  the 

TIMER 

button. “1ON” will appear at the left side of the display. This is the start time of the first 

programmed sleep block (the time you want the spa to enter the sleep mode). 

2.   Press  the 

DAY 

button to select the days on which this sleep program will operate.There are15 settings to 

choose from.   

3.  Press the 

HOUR

 button to set the hour of the desired time to enter sleep mode. 

4.  Press the 

MIN 

button to set the minutes of the desired time to enter sleep mode. 

5.   Now the start time has been set, press the 

TIMER 

button again. “1OFF” will appear on the display.This is 

the end time of the first programmed sleep block (the time you want the spa to resume normal operation). 

6.   Repeat the same procedure (2 to 4 above) until the “1OFF” time is set. (Becareful to set the same days 

as used in the “1ON” time). 

7.   Your timer gives you upto 8 different programmable periods.You can use all 8 settings,or as few as you like.  
8.   To Review your set programs press the 

TIMER 

button and keep pressing it to advancet hrough each 

setting. 

IMPORTANT NOTE:

 The “MANUAL” button on the clock can be used to override the programmed sleep settings. 

It is very important to ensure that the clock is set to “AUTO” so that the programmed times can operate. If the 

clock is manually set to ON then the pool will stay in sleep mode and THE WATER WILLGO COLD. If it is left in 

“OFF” then the pool will not enter the sleep mode. The clock does not return to “AUTO” byitself. 

NOTE:

 If the “MANUAL” button on the clock is used the spa will not return to the programmed settings until 

the next programmed time after being returned to Auto. 

Содержание SpaPOWER SP400P

Страница 1: ...SP400P SP601 Models SP400P Q400PAU 10 Q400PAU 15 SP601AU 15 SP601AU 15T Q601AU 20 SP601AU 20T Q601AU 15 Q601AU 30 SP601AU 30T User s Guide...

Страница 2: ...that young children or infirm persons do not have access to the button coin battery If swallowed a lithium button coin battery can cause severe or fatal injuries within 2 hours If you think a button...

Страница 3: ...ter is below7 0 is acid above7 0 isalkaline Low pH will cause corrosion of any metalwork in the water element thermostat pockets High pH will cause scale formation and cloudywater Total Alkalinity Thi...

Страница 4: ...ll be at the correct temperature when ever he or she wants to use it 2 1 Adjusting Set Temperature The Spa Power controller gives the user direct control of the pool temperature from the poolside cont...

Страница 5: ...e pressing the pump button will deactivate auto mode and set the pump running in Manual Mode The auto LED is orange when auto mode is enabled and off when in Manual Mode When the pump is in standby mo...

Страница 6: ...d 24HR circulation pump fitted Pushing the pump button three times cycles the pump through its two speeds then off The pump LED is green when the pump is running in low or high speed and off when pump...

Страница 7: ...either on or off The Spa Power Variable Coloured light is a light that has the ability to change between 12 different colours and white see below for user instructions The multi function Light Button...

Страница 8: ...crystal clear for each and every spa use A near silent energy efficient circulation pump constantly passes water through the filter and since the circulation pump runs all the time except for when the...

Страница 9: ...the TIMER button 1ON will appear at the left side of the display This is the start time of the first programmed sleep block the time you want the spa to enter the sleep mode 2 Press the DAY button to...

Страница 10: ...n contact your spa pool supplier Error 4 No Water Sensor This error indicates a problem with the optical water sensor in the heater The problem may by caused by the sensor being disconnected or by dam...

Страница 11: ...11...

Страница 12: ...d by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none o...

Отзывы: