5.2 Indicator Light
A small red dot in the bottom corner of the digital readout indicates when the light is turned on. If left on the
light will automatically switch off after 30 minutes.
ON
6. LIGHT OPERATION
6.1 No 24hr Circulation Pump Fitted
The Spa Power controller automatically maintains the filtration/sanitising of the spa pool water. The minimum
amount of filtration time is programmable by the user and can be adjusted between 0 and 15 minutes per hour
(0 to 6 hours per day). In order to maintain correct filtration of the pool water, the controller monitors the time
for which the pump runs in normal pool operation. If the pump has only run for a short time, the system will
automatically run the pump for an additional period every hour to reach the minimum filtration time set by the user.
6.1.1 Adjusting Minimum Filtration Time (No 24hr circulation pump fitted)
First push the Down
andAir/Aux
buttons together to display the filtration time setting on the
digital readout
Press both buttons
simultaneously
Press both buttons
simultaneously
The default setting is 10 minutes per hour (= 4 hours per day). Holding down the Up Button
or Down
Button
will adjust the filtration time setting between 0 and 15 minutes per hour. (= 0 to 6 hrs per day).
6.1.2 Clean Up Cycle
If desired, a clean up cycle can be initiated to filter the water after the spa pool has been used.This is done
by simply pushing the Pump Button
to leave auto mode and switch on the pump. This will circulate the
water through the filter for 90 minutes.After 90 minutes the system will return to auto mode and maintain the
temperature ready for the next time the spa pool is used.
6.2 24hr Circulation Pump Fitted
The Spa Power controller continuously filters the spa pool to ensure the water is clean and crystal clear for
each and every spa use. A near silent energy efficient circulation pump constantly passes water through the
filter and since the circulation pump runs all the time (except for when the time clock has been set to sleep
or in an error condition) and the heater is controlled automatically there is no need for any user controls for
these features. With a 24hr circulation pump fitted there is no need to program any filtration cycles,and the
noise of a large jet pump running during filtration has bee nremoved.
6.3 My Spa Is Too Hot In Summer!
During warm periods of the year there may be times when the actual water temperature exceeds the desired
temperature set by the user. E.g. If the spa is set to heat to 35
o
C , but the actual water temperature is hotter
than 35
o
C. Please consider this - In the winter your spa gets cold because the air temperature is cold. To
combat this we heat the water and keep the spa covered when not in use. If the spa is turned off and the
ambient temperature is 15
o
C, eventually the spa water will lose heat until it too is 15
o
C. In the summer
the same applies but in reverse - you can turn the heater down, even turn the pump off, but if the ambient
daytime temperature is 35
o
C - 42
o
C then the spa water will also remain at that temperature. Manufacturers
make no attempt to supply a system that cools water. The quickest way to combat the problem is to change
the water, but even this new water will eventually heat up to the air temperature.Turn the set temperature
down so the heater does not come on. Reduce the minimum filtration time (non circ pump models only) so
the pump runs less.The less the pump runs the more the water will cool. If the night time temperature is
low, leave the cover off the spa to let heat escape, but put it back on during the day to keep heat out. If the
optional time clock is fitted increase the sleep time period otherwise turn the spa off overnight. Also make