3. INSTALLATION
•
The unit should be installed by a professional and in accordance with current accepted practices (IEC Standard
364-7-702 and NFC 1500 Section 702).
•
The power supply should include electrical protection and isolating gear in accordance with the regulations in
force.
•
See General Installation Diagram, Appendix 1
•
First select a place inside the plant room where you can fix the switch cupboard at a height at which it can be
accessed and read easily.
•
Connect the control unit in parallel with the filter circuit pump such that the unit only starts when the pump is in
operation.
•
IMPORTANT: The cell is connected to the hydraulic circuit after all the other items of equipment (pump, filter,
heating, blower, etc.), just before the hydraulic circuit return into the pool.
•
The cell must be fixed horizontally at a level just slightly above the level of the filter.
•
Fix cell in accordance with the direction of the arrow located on the body of the cell; this shows the direction in
which the water flows in the cell.
•
You must position the cell such that it can be removed easily for cleaning purposes, should that become necessary.
•
Connect the electrode power input to the switch cupboard.
•
MPS models: Connect the two plugs to the connectors on the cell.
•
Connect the safety device to the terminal provided for this purpose on the cell.
NOTE:
One of the adapters of the cell is made with a bolt. Install this Adaptor in between the cell housing (opposite
side to the threaded side of the cell housing) and pipe. The bolt is to make a connection to an independent earth –
Refer to installation drawing
•
To connect blanket switch :
>Push “banana” plugs into the bottom of the
black-black “banana” sockets OR
>Push wires into the holes at sides of the black-black terminals and screw down to fasten
NOTE:
Plugs or wires can be connected into either of the black terminals
Содержание ProMatic MPS 16
Страница 2: ......
Страница 6: ...6...
Страница 17: ...17 9 APPENDIX 1 Independent earth MPS50CE Cell...
Страница 18: ...18 ProMatic Mod les MPS Electrolyse au sel pour piscines Manuel d installation et d entretien FRAN AIS...
Страница 29: ...29 MPS50CE Cell...
Страница 33: ...33 MPS50CE Zelle...
Страница 42: ...42 ProMatic MODELOS MPS Tratamento com base na adi o de sal MANUAL DE INSTALA O E DE MANUTEN O PORTUGU S...
Страница 53: ...53 ANEXO MPS50 Celula...
Страница 65: ...65 9 ALLEGATO 1 MPS50 Celula...
Страница 66: ...66 ProMatic Modelos MPS Manual de instalaci n y de mantenimiento ESPA OL...
Страница 75: ...75 MPS50 Celula...