manualshive.com logo in svg
background image

2

 

 

Congratulations on the purchase of a quality product from the Davey Water 
Products range of Pool Equipment. You are assured many years of reliable 
and super-efficient performance from your Davey ProMaster VSD Pool pump 
with Bluetooth.

 

This pump is Bluetooth enabled, so you will be able to set and control the pump 
functions  from  your  smart  device.  Bluetooth  is  a  wireless  communication 
protocol  that  enables  communication  between  devices.  This  function  is 
supported by any device that can download an app from IOS or Android App 
Store.

 

Read these instructions in their entirety before switching on this pump. If you 
are uncertain as to any of these installation and operating instructions please 
contact your Davey dealer or the appropriate Davey office as listed on the back 
of this document.

 

The Davey ProMaster has been designed to circulate swimming pool and spa 
water in conditions set out in the Australian Standard for swimming pool water 
quality AS 3633 or equivalent. They should not be used for any other purpose 
without  first  consulting  your  Davey  Dealer  or  the  Davey  Customer  Service 
Centre.

 

Every  Davey  ProMaster  pool  pump  is  thoroughly  water  tested  against  a 
number  of  flow,  pressure,  voltage,  current  and  mechanical  performance 
parameters.  Davey’s  advanced  pump  manufacturing  technology  provides 
reliable and efficient pumping performance that lasts and lasts.

 

 

Saving Energy with your Davey ProMaster VSD Pool Pump

 

The  Davey  ProMaster  VSD  pool  pump  is  a  super-efficient  pump  utilising  a 
state of the art infinitely variable AC motor that provides lower levels of noise, 
reduced operating costs and lower greenhouse emissions than traditional pool 
pumps.

 

Due  to  its  ability  to  run  at  lower  speeds  than  conventional  pumps,  your 
ProMaster pump will also experience less mechanical wear and tear due to 
less stress on the internal mechanical components.

 

To  achieve  energy  efficient  pumping  is  easy.  Simply  run  the  filtration 
pump at a lower speed, but run it for longer (see table on page 5) than a 
conventional  fixed  speed  pump  to  “turn  over”  your  pool  water  for 
adequate filtration and sanitisation.  

The result is lower energy use and lower operational costs.

 

 

 

 

Содержание ProMaster PM400BT

Страница 1: ...ay cause serious bodily injury and or property damage This pump requires professional expertise for installation and maintenance The installation of this product should be carried out by a person know...

Страница 2: ...y should not be used for any other purpose without first consulting your Davey Dealer or the Davey Customer Service Centre Every Davey ProMaster pool pump is thoroughly water tested against a number o...

Страница 3: ...pressure than you are used to This is also NORMAL The lower system pressure is simply a result of the lower speed and flow rate produced by the pump While running at the lower speed settings you will...

Страница 4: ...In the interest of safety we advise that all brands and types of pool pumps must be installed in accordance with AS NZS 3000 known as the national wiring rules or equivalent local standards All elect...

Страница 5: ...ools water quality states that The minimum turnover rate shall be a single turnover of the full volume of the pool water within the period that the pump would normally be operating The tables below pr...

Страница 6: ...1 128W 0 17hp Speed Setting 1 125w 0 17hp Speed Setting 5 524W 0 70hp Speed Setting 5 724w 0 97hp Speed Setting 10 1111W 1 49hp Speed Setting 10 1650w 2 2hp Backwash Setting 1320w 1 77hp Backwash Sett...

Страница 7: ...0mm 76mm MINIMUM 1 Do not install 90 elbows directly into pump inlet Elbows should be no closer than 250mm to the inlet 2 Flooded suction systems should have gate valves installed on suction and disch...

Страница 8: ...signed to accept 40mm 50mm PVC fittings When plumbing the discharge pipe ensure that the pipework does not interfere with the pumps speed dial The use of any pipe smaller than those specified above is...

Страница 9: ...t c The pump enclosure has adequate drainage in the event of leakage c Any transport plugs are removed c The pipe work is correctly sealed and supported c The pump is filled with water to the inlet c...

Страница 10: ...r operation Speed 5 to 8 Backwashing your media filter Backwash Speed Manually cleaning your pool Speed 9 to 10 Water Feature operation Spa Jet operation In floor cleaning systems Solar pool heating U...

Страница 11: ...07 0 19 145 3 0 130 Dial 3 0 39 293 0 28 205 4 1 151 Dial 4 0 53 398 0 37 279 5 2 169 Dial 5 0 70 524 0 49 367 4 7 188 Dial 6 0 88 655 0 61 459 6 4 205 Dial 7 1 08 807 0 76 565 7 5 220 Dial 8 1 26 936...

Страница 12: ...ial 4 0 69 514 0 48 360 3 6 255 Dial 5 0 97 724 0 68 507 4 7 290 Dial 6 1 21 905 0 85 634 5 4 314 Dial 7 1 61 1201 1 13 841 6 7 348 Dial 8 1 97 1469 1 38 1028 7 8 373 Dial 9 2 17 1620 1 58 1180 7 9 37...

Страница 13: ...off the motor is transferred into the pool water helping to reduce pool heating energy costs Constant Flow Speed Compensation PM400BT model only Helps to overcomes friction loses experienced as debri...

Страница 14: ...however only one device can control the pump at any given time The language and time of the app is the same as your device setting The measuring units are automatically defaulted to your device s reg...

Страница 15: ...e and you can manually adjust the speed by pressing the buttons In manual mode the pump will run at the set speed even if the phone is not in range Anytime the dial is switched to the Bluetooth positi...

Страница 16: ...device and the pump can take up to 20 secondsdepending on the schedule selected Note The row at the bottom of the screen indicates a summary of where the schedule is by day and by hour This summary s...

Страница 17: ...xternal Timer Present Swipe this on or off depending on whether you are using an external timer chlorinator Disconnect Function The disconnect from pump function can be used to 1 Allow another device...

Страница 18: ...18 Pump Fault Finding In the instance that there is a fault the following screen will appear with text description below the fault indicating how to remedy...

Страница 19: ...ousing Figure 1 RJ45 Plug Installed in housing from rear It is recommended to keep the cable length between the pump and external pool controller or heater as short as possible There are two major pin...

Страница 20: ...d the digital input pin 2 Connect the switched contacts of a relay between the 24V pin and the digital input The fixed speeds as a proportion of full speed are Input 1 Pin 7 Input 2 Pin 6 Input 3 Pin...

Страница 21: ......

Страница 22: ...en all air is expelled from the leaf basket connect the pool cleaner hose firmly into the skimmer plate or dedicated wall suction 3 Select the speed setting that enables best performance from your suc...

Страница 23: ...damage not covered by warranty Trouble Shooting If the pump runs but there is no water flow or water flow is reduced the following condition may apply 1 The filter requires backwashing or it is blocke...

Страница 24: ...seconds 3 Blockage is preventing the pump fromrotating Removal of the Pump from Pipework Should it be necessary to remove the pump follow these instructions 1 Switch off the power and remove the plug...

Страница 25: ...rst a Make sure that any pressure gauges are in working condition and the operating pressure is within limits as specified on the product b Make sure that each suction inlet and main drain has a cover...

Страница 26: ...NOTES...

Страница 27: ...or abrasive water or other liquid lightning or high voltage spikes or unauthorised persons attempting repairs Where applicable your Davey product must only be connected to the voltage shown on the na...

Страница 28: ...ce Ph 33 0 4 72 13 95 07 Fax 33 0 4 72 33 64 57 Email info daveyeurope eu Website daveyeurope eu INTERNATIONAL Australian Head Of ce Ph 613 9730 9124 Fax 613 9753 4248 Email export davey com au Websit...

Отзывы: